3 Specifications
3 - 98
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User’s Manual (I586)
400 VAC
R88D-
1SN06F-ECT
R88A-
PD4007
3.0 A
27 mH
2.0 kg
AWG 16 to 10,
1.3 to 5.5 mm
2
R88D-
1SN10F-ECT
R88A-
PD4015
4.7 A
14 mH
2.0 kg
R88D-
1SN15F-ECT
R88D-
1SN20F-ECT
R88A-
PD4022
6.9 A
10.1 mH
2.9 kg
AWG 14 to 10,
2.0 to 5.5 mm
2
R88D-
1SN30F-ECT
R88A-
PD4037
11.6 A
6.4 mH
4.5 kg
*1. Use wires with a rated voltage of 600 V or higher.
An example of using heat-resistant polyvinyl chloride insulated wires (HIV) at the ambient temperature of 50°C.
3-6-3
Terminal Block Specifications
Symbol
Name
Remarks
U
DC Reactor
connection terminals
Terminal block screw: M4
Tightening torque: 1.4 to 1.8 N·m
X
Applicable Servo Drive
DC Reactor
Wire size
*1
Voltage
Model
Model
Rated
current
Inductance
(0% to 20%)
Weight
Summary of Contents for R88D-1SN01H-ECT