Appendices
A - 134
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User’s Manual (I586)
Event name
General Input Allocation Duplicate Error
Event code
38780000 hex
Description
More than one function input is allocated to one general input.
Source
EtherCAT Master Function Mod-
ule
Source details
Slave
Detection
timing
At power ON
Error
attributes
Level
Minor fault
Recovery
Error reset
(after cycling
slave power)
Log category
System log
Effects
User program
Continues.
Operation
Power drive circuit is OFF
Indicators
EtherCAT NET RUN
EtherCAT NET ERR
EtherCAT LINK/ACT
---
---
---
System
-defined
variables
Variable
Data type
Name
None
None
None
Cause and
correction
Assumed cause
Correction
Prevention
More than one function input is
allocated to one general input
Correct the duplicate general input
allocation.
Confirm that there is no duplicate
allocation when setting a function
input.
Attached
information
Attached Information 1: Cause Details
1: General Input 1 (IN1) Allocation Duplicate Error
2: General Input 2 (IN2) Allocation Duplicate Error
3: General Input 3 (IN3) Allocation Duplicate Error
4: General Input 4 (IN4) Allocation Duplicate Error
5: General Input 5 (IN5) Allocation Duplicate Error
6: General Input 6 (IN6) Allocation Duplicate Error
7: General Input 7 (IN7) Allocation Duplicate Error
8: General Input 8 (IN8) Allocation Duplicate Error
Precautions/
Remarks
AL status code: -, Error No.: 3300 hex
Event name
General Output Allocation Duplicate Error
Event code
38790000 hex
Description
More than one function output is allocated to one general output.
Source
EtherCAT Master Function Mod-
ule
Source details
Slave
Detection
timing
At power ON
Error
attributes
Level
Minor fault
Recovery
Error reset
(after cycling
slave power)
Log category
System log
Effects
User program
Continues.
Operation
Power drive circuit is OFF
Indicators
EtherCAT NET RUN
EtherCAT NET ERR
EtherCAT LINK/ACT
---
---
---
System
-defined
variables
Variable
Data type
Name
None
None
None
Cause and
correction
Assumed cause
Correction
Prevention
More than one function output is
allocated to one general output
Correct the duplicate general out-
put allocation.
Confirm that there is no duplicate
allocation when setting a function
output.
Attached
information
Attached information 1: Cause details
1: General Output 1 (OUT1) Allocation Duplicate Error
2: General Output 2 (OUT2) Allocation Duplicate Error
3: General Output 3 (OUT3) Allocation Duplicate Error
4: General Output 4 (OUT4) Allocation Duplicate Error
Precautions/
Remarks
AL status code: -, Error No.: 3309 hex