4 Configuration and Wiring
4 - 12
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User’s Manual (I586)
Satisfy the space conditions around Servo Drives that are described in
4-1-1 Servo Drive Installation
Use the attached exclusive screws when you mount the Servo Drive to the Noise Filter. The tightening
torque for the exclusive screws is 1.2N·m±10%.
Install the Noise Filter on the vertical metal surface.
Turn the LINE side of Noise Filter in the gravity direction (downward) as shown in the following figure.
4-1-5
Footprint-type Noise Filter Installation Conditions
Mounting Direction
Noise filter model
Wire size
Length
Strip length
R88A-FI1S103/-FI1S105/
-FI1S202/-FI1S203
AWG 16
Approx. 300 mm
8.5±0.5 mm
R88A-FI1S109/-FI1S208
AWG 14
Approx. 300 mm
8.5±0.5 mm
R88A-FI1S116/-FI1S216
AWG 10
Approx. 300 mm
13.7±0.5 mm
R88A-FI1S309
AWG 12
Approx. 300 mm
13.7±0.5 mm
Lead wire
*2
Noise filter
Side view
Servo Drive
*1. Power supply side
*2. The specifications of the lead wires are shown below.
Metal plate
Gravity
direction
LINE
*1
Summary of Contents for R88D-1SN01H-ECT