This is a programming example in which the STO function of the 1S-series Servo Drive is operated
from the Safety Controller.
Precautions for Correct Use
• Design programs for the safety controller so that the STO function is not canceled automati-
cally even when the emergency stop switch is released.
• Design programs for the safety controller so that the STO function is not canceled automati-
cally when a Servo Drive failure is detected through the EDM output.
Programming Example
SF_EmergencyStop
SF_EDM
STO
S_EDM1
S_EStop In
Reset
Reset
Reset
S_EStop Out
S_EDM Out
S_OutControl
EDM