4 Configuration and Wiring
4 - 40
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User’s Manual (I586)
The value of the inrush current varies depending on the input voltage to the Servo Drive. The values
shown above are for the following input voltages.
• Select a leakage breaker which is made for high frequency and surge resistance.
• When you determine the threshold value for leakage current detection, add the total leakage current
from all devices that are connected to the same breaker.
• Refer to the catalogs from the manufacturers for details on how to select a leakage breaker and
ensure a sufficient margin.
R88D-1SN30F-ECT
32 A
*1. If an external regeneration resistor is attached, the inrush
currents of the main circuit power supplies in the above table
will be increased.
(Increase in current =
√
2 × main circuit power supply volt-
age/external regeneration resistance)
Model
Main circuit power
supply voltage
R88D-1SN
L-ECT
120 VAC
R88D-1SN
H-ECT
240 VAC
R88D-1SN
F-ECT
480 VAC
Leakage Breaker
Servo Drive
model
(R88D-)
Servomotor
model
(R88D-)
Input power
Leakage current
(3 m cable)
Increase per 10 m of
cable length
1SN01L-ECT
1M10030S
Single-phase 100 V
0.6 mA
0.3 mA
1SN02L-ECT
1M20030S
Single-phase 100 V
1SN04L-ECT
1M40030S
Single-phase 100 V
1SN01H-ECT
1M10030T
Single-phase 200 V
1.5 mA
1.3 mA
3-phase 200 V
1SN02H-ECT
1M20030T
Single-phase 200 V
3-phase 200 V
1SN04H-ECT
1M40030T
Single-phase 200 V
3-phase 200 V
1SN08H-ECT
1M75030T
Single-phase 200 V
3-phase 200 V
1SN10H-ECT
1L1K030T
3-phase 200 V
1M1K020T
3-phase 200 V
1M90010T
3-phase 200 V
Servo Drive model
Inrush current (Ao-p)
Main circuit power supply
Summary of Contents for R88D-1SN01H-ECT