NX-8E Control Panel 

Installation and Startup

Summary of Contents for NetworX Series

Page 1: ...NetworX Series NX 8E Control Panel Installation and Startup...

Page 2: ...ry information of GE Interlogix USA and is furnished to its customer solely to assist that customer in the installation testing operations and or maintenance of the equipment described This document s...

Page 3: ...UICK START INSTALLATION 12 X PROGRAMMING LOCATIONS 13 Table X 1 COMMUNICATOR FORMAT SELECTIONS 13 REPORTING EVENTS TO PHONE NUMBER 1 14 REPORTING EVENTS TO PHONE NUMBER 2 15 REPORTING EVENTS TO PHONE...

Page 4: ...tion Indicates a procedure practice condition or statement that if not strictly observed could result in damage to or destruction of equipment or property This symbol indicates general warnings and ca...

Page 5: ...KIT NX 8E Control NX 148E LCD Keypad 16 5V 40VA Transformer NX 108E 8 Zone LED Keypad NX 116E 16 Zone LED Keypad NX 124E 24 Zone LED Keypad NX 148E Alphanumeric LCD Keypad NX 200 Zone Doubling Kit Inc...

Page 6: ...n is not required The Cancel and Abort features in locations 23 and 40 respectively must be enabled to permit this Auto feature to work For proper operation of these features ADialer Delay must be ena...

Page 7: ...be programmed as supervised Entry Guard This unique low level arming mode has been developed to reduce the most common source of false alarms When armed with the AInstant LED on the opening of any zon...

Page 8: ...e 18 Log Full Report A report can be sent to the central station when the event log is full See location 37 page 21 Lost Clock Service Light The NX 8E can be programmed to illuminate the Service LED w...

Page 9: ...feat If enabled only one call is required to defeat the answering machine To use this feature you must have a Hayes 1200 Smart Modem or a CADDX 1200 module From the computer call the panel as normal W...

Page 10: ...Enable Armed Status Suppression will not allow the keypad to display faulted or bypassed zones when the system is armed 6 Enable Panic Fire Medical Beeptone will sound a short beep to verify that the...

Page 11: ...you to the partition enable This tells the system what partition this user can arm disarm LEDs 1 8 illuminate for each partition that the user has authorization for To change any of these numbers pres...

Page 12: ...ent and display its data This procedure is repeated until the last segment is reached Pressing the key will exit from this location and the Armed LED will illuminate again waiting for a new programmin...

Page 13: ...NX 8E CONTROL 11 PROGRAMMING EXAMPLE TO BE INSERTED HERE...

Page 14: ...tion of a feature will make the corresponding LED illuminate feature ON Press the number again and the LED will extinguish feature OFF You will see that numerous features can be selected from within o...

Page 15: ...sabled 1 Universal 4 2 Two digit event code 1800hz transmit 2300hz handshake double round parity 40pps 2 3 1 fast or 4 1 One digit event code 1900Hz transmit 1400Hz handshake double round parity 20pps...

Page 16: ...Trouble Restores 5 Power Fail Low Battery Power Restore and Low Battery Restore 6 Bell Cut Telephone Line Cut Bell Cut Restore Telephone Line Restore 7 Test Reports 8 Start and End programming Downloa...

Page 17: ...e 1 then repeating until the total number of attempts designated in Segment 1 is completed REPORTING EVENTS TO PHONE NUMBER 2 Phone 2 can be used to back up Phone 1 or for a second receiver to multi r...

Page 18: ...e 3 is dialed LOCATION 15 DIAL ATTEMPTS BACKUP CONTROL FOR PHONE 3 2 segments numerical data Segment 1 Dial Attempts Segment 1 of Location 15 is used to enter the number of dial attempts 1 to 15 attem...

Page 19: ...ition 1 2 Partition 2 3 Partition 3 4 Partition 4 5 Partition 5 6 Partition 6 7 Partition 7 8 Partition 8 LOCATION 18 CUSTOM COMMUNICATOR FORMAT See locations 2 8 14 Segment 1 1 On for 1800hz transmit...

Page 20: ...RNING THE CALLBACK PHONE NUMBER SHOULD ALWAYS BE REVIEWED FOR ACCURACY BEFORE DISCONNECTING L LOCATION 23 PARTITION 1 FEATURE AND REPORT SELECTIONS 5 segments feature selection data Location 23 is use...

Page 21: ...ven if enabled in Segment 1 of Location 23 5 INTERIOR FOLLOWER WITH AUTO BYPASS ENABLED This zone will be instant when the system is armed and no entry or exit delay is being timed It is delayed durin...

Page 22: ...he Fire LED indicating a trouble if the zone is open 25 CHIME ONLY Creates no alarm regardless of the armed state of the control panel It will chime anytime it is faulted and will display on the keypa...

Page 23: ...24 Segments 1 8 1 Partition 1 3 Partition 3 5 Partition 5 7 Partition 7 2 Partition 2 4 Partition 4 6 Partition 6 8 Partition 8 L LOCATION 31 ZONES 25 32 ZONE TYPE GROUP 8 segments numerical data Loca...

Page 24: ...wireless arming 2 times for disarming Segment 2 1 On if siren driver should be a voltage output Off if on board siren driver enabled 2 On if siren sounds for expander trouble required for UL installa...

Page 25: ...in minutes 0 255 minutes 0 no test Segment 2 AC Fail report delay in minutes 0 255 minutes Segment 3 Power Up Delay in seconds 0 60 seconds 0 no power up delay Segment 4 Siren Time in minutes 1 255 m...

Page 26: ...er 4 or 6 digits If the 6 digit code option is enabled in Location 41 THIS CODE MUST CONTAIN SIX 6 DIGITS If the 6 digit option is not enabled in location 41 the last 2 digits will be ignored If the d...

Page 27: ...46 Programming a 0 makes the output follow the event Table XI 1 AUXILIARY OUTPUT EVENT SELECTION DATA EVENT DATA EVENT DATA EVENT 0 Burglary Alarm 18 Entry 36 Telephone Line Fault 1 Fire Alarm 19 Exit...

Page 28: ...the hour of the closing auto arm time Segment 2 Program the minutes after the hour of the closing auto arm time LOCATION 54 DAYS OF THE WEEK EACH PARTITION IS OPEN 8 Segments feature selection data L...

Page 29: ...2 format Refer to the box at the top of page 27 Segment 1 Partition 1 Segment 3 Partition 3 Segment 5 Partition 5 Segment 7 Partition 7 Segment 2 Partition 2 Segment 4 Partition 4 Segment 6 Partition...

Page 30: ...ents numerical data Location 69 contains the digits for a 4 2 format that will be sent if Low Battery Reporting is enabled Segments 1 2 contain the digits of the Low Battery Reporting Segments 3 4 con...

Page 31: ...N 79 AUTOTEST COMMUNICATOR CODE 2 segments numerical data Location 79 contains the digits for a 4 2 format that will be sent if the Autotest or Manual Test is enabled Refer to the box on page 27 LOCAT...

Page 32: ...times for partition 1 will be used Segment 1 Entry time 1 Entry time that will be used when a Delay 1 zone type initiates an entry delay Segment 2 Exit time 1 Exit time that will be used for all zone...

Page 33: ...the account code is 6 digits long program all 6 segments LOCATION 99 PARTITION 5 FEATURE AND REPORTING SELECTIONS 5 SEGMENTS NUMERICAL DATA Location 99 is used to enable certain features that can be...

Page 34: ...he entry and exit times for partition 1 will be used Segment 1 Entry Time 1 Entry time that will be used when a Delay 1 zone type initiates an entry delay Segment 2 Exit Time 1 Exit time that will be...

Page 35: ...On if Zone Type is force armable 8 On if Zone Type is entry guard Segment 3 1 On enables Fast Loop Response 50mS Off 500mS 2 On enables Double End Of Line Tamper zone Mainly used for tamper on wireles...

Page 36: ...segments feature selection data Use Zone Type Characteristic Selections described in Location 111 page 33 LOCATION 124 ZONE TYPE 8 ALARM EVENT CODE 1 segment numerical data Location 124 contains the...

Page 37: ...A report The desired event code should be chosen from the list on page 70 The zone ID will be that zone that is in alarm If 4 2 format is being used refer to Location 110 on page 33 for details LOCATI...

Page 38: ...A report The desired event code should be chosen from the list on page 70 The zone ID will be that zone that is in alarm If 4 2 format is being used refer to Location 110 on page 33 for details LOCATI...

Page 39: ...70 The zone ID will be that zone that is in alarm If 4 2 format is being used refer to Location 110 on page 33 for details LOCATION 167 ZONE TYPE 29 CHARACTERISTIC SELECT 5 segments feature selection...

Page 40: ...t 8 is for zone 80 Default Zone Types are found in the table on page 19 To customize a Zone Type see page 33 LOCATION 177 PARTITION SELECT ZONES 73 80 8 segments of feature selection data Location 177...

Page 41: ...es 105 112 reside in A zone may reside in any combination of the 8 partitions If a burglary zone resides in more than 1 partition it will only be active when all partitions are armed A zone that resid...

Page 42: ...one 137 and Segment 8 corresponds to zone 144 Segments 1 8 1 Partition 1 3 Partition 3 5 Partition 5 7 Partition 7 2 Partition 2 4 Partition 4 6 Partition 6 8 Partition 8 L LOCATION 194 ZONES 145 152...

Page 43: ...artition 1 3 Partition 3 5 Partition 5 7 Partition 7 2 Partition 2 4 Partition 4 6 Partition 6 8 Partition 8 L LOCATION 202 ZONES 177 184 ZONE TYPE 8 segments numerical data Location 202 contains the...

Page 44: ...AUTOMATION PROTOCOL 1segmentofnumericaldata The NX 8E home automation protocol can operate in one of two possible modes binary or ASCII Consult the home automation application information to determine...

Page 45: ...t 1 DATA SUPPORTED REQUEST COMMAND 1 Reserved 2 Interface Configuration Request 3 Reserved 4 Zone Name Request 5 Zone Status Request 6 Zones Snapshot Request 7 Partition Status Request 8 Partitions Sn...

Page 46: ...be left at the factory default If the LCD keypad is selected as something other than partition 1 keypad 1 program the appropriate address in location 212 Select the address from the following chart KE...

Page 47: ...ition 1 2 Partition 2 3 Partition 3 4 Partition 4 5 Partition 5 6 Partition 6 7 Partition 7 8 Partition 8 L 6 14 PHONE 2 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 __ __ __ __ __ __ _...

Page 48: ...To Program Segment 2 Circle Numbers To Program 1 ON 1800hz transmit OFF 1900hz 2 ON 2300hz handshake OFF 1400hz 3 ON cksum parity OFF double round parity 4 ON 2 digit event code OFF 1 digit code 5 Res...

Page 49: ...5 RESERVED L 24 19 ENTRY EXIT TIMERS Segment 1 Entry Time 1 30 Segment 2 Exit Time 1 60 Segment 3 Entry Time 2 30 Segment 4 Exit Time 2 60 Segments 5 6 Reserved L 25 20 ZONES 1 8 ZONE TYPES 3 5 6 6 6...

Page 50: ...8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 L 33 21 ZONES 33 40 ZONE TYPES 6 6 6 6 6 6 6 6 _ _ _ _ _ _ _ _ ZONES...

Page 51: ...ogram 1 2 3 4 5 6 7 8 Box Tamper report enabled AC Fail report enabled Low Battery report enabled Auxiliary power over current report enabled Siren supervision report enabled Telephone Line Cut report...

Page 52: ...ements 0 255 3 _ Segment 8 Dialer delay 0 255 seconds 0 _ Segment 9 Fire Alarm Verification Time 120 255 sec 0 _ Segment 10 Listen In Time 0 255 seconds 0 _ Segment 11 Zone Monitor Timer 0 255 Days L...

Page 53: ...y between opening and closing time Invert auxiliary output 0 volts going to 12 volts when activated Reserved Reserved 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 AUXILIARY OUTPUT 1...

Page 54: ...1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 COMMUNICATOR CODES FOR SLOW SPEED FORMATS ONLY The digit programmed in each of the following locations will be sent as t...

Page 55: ...Segment 7 Partition 7 Trouble Code 0 _ 27 Segment 8 Partition 8 Trouble Code 0 _ SENSOR LOW BATTERY COMMUNICATOR CODE SLOW SPEED FORMATS ONLY Segment 1 Partition 1 Sensor Low Battery Code 0 _ Segment...

Page 56: ...Code for Partition 3 0 _ Segment 4 Closing Code for Partition 4 0 _ Segment 5 Closing Code for Partition 5 0 _ Segment 6 Closing Code for Partition 6 0 _ Segment 7 Closing Code for Partition 7 0 _ Seg...

Page 57: ...6 7 8 Tamper Cancel Recent Closing Exit Error Segment 4 1 2 8 Late to Close Early to Open Reserved 93 30 Segment 5 RESERVED PARTITION 3 ENTRY EXIT TIMERS Segment 1 Entry Time 1 0 _ Segment 2 Exit Tim...

Page 58: ...7 8 Tamper Cancel Recent Closing Exit Error Segment 4 1 2 8 Late to Close Early to Open Reserved 99 31 Segment 5 RESERVED PARTITION 5 ENTRY EXIT TIMERS Segment 1 Entry Time 1 0 _ Segment 2 Exit Time...

Page 59: ...6 7 8 Tamper Cancel Recent Closing Exit Error Segment 4 1 2 8 Late to Close Early to Open Reserved 105 32 Segment 5 RESERVED PARTITION 7 ENTRY EXIT TIMERS Segment 1 Entry Time 1 0 _ Segment 2 Exit Tim...

Page 60: ...efeat Delays alarm activation 60 seconds Zone acts as request to exit input 5 6 7 8 Reserved Reserved Reserved Reserved Segment 5 Reserved THE DEFAULTS LISTED IN THE ODD NUMBERED LOCATIONS BELOW REPRE...

Page 61: ...E 21 CHARACTERISTIC SELECT 24 15 78 __ __ __ __ __ 152 36 ZONE TYPE 22 ALARM EVENT CODE 20 __ 153 36 ZONE TYPE 22 CHARACTERISTIC SELECT 24 15 78 __ __ __ __ __ 154 36 ZONE TYPE 23 ALARM EVENT CODE 21...

Page 62: ...3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 L 176 38 ZONES 73 80 ZONE TYPES 6 6 6 6 6 6 6 6 _ _ _ _ _ _ _ _ ZONES 73 80...

Page 63: ...5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 L 184 39 ZONES 105 112 ZONE TYPES 6 6 6 6 6 6 6 6 _ _ _ _ _ _ _ _ ZONES 105 112...

Page 64: ...3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 L 192 40 ZONES 137 144 ZONE TYPES 6 6 6 6 6 6 6 6 _ _ _ _ _ _ _ _ ZONES 137...

Page 65: ...3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 L 200 41 ZONES 169 176 ZONE TYPES 6 6 6 6 6 6 6 6 _ _ _ _ _ _ _ _ ZONES 169...

Page 66: ...Wednesday Thursday Friday Saturday Reserved 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 SERIAL PORT ENABLE 0 _ 207 4...

Page 67: ...Set User Code Command with PIN 6 Set User Code Command without PIN 7 Set User Authorization Comm with PIN 8 Set User Authorization Comm without PIN 1 2 Reserved 3 Store Communication Event Command 4 S...

Page 68: ...NX 8E CONTROL 66 XIII NX 8E WIRING DIAGRAM...

Page 69: ...dividually this terminal is limited to 1 Amp Combined this terminal and KP POS are limited to 2 amps total current ZONE 8 Connect to one side of zone 8 loop Connect the other side to com terminal Open...

Page 70: ...65 113 161 18 66 114 162 19 67 115 163 20 68 116 164 21 69 117 165 22 70 118 166 23 71 119 167 24 72 120 168 25 73 121 169 26 74 122 170 27 75 123 171 28 76 124 172 29 77 125 173 30 78 126 174 31 79...

Page 71: ...mber 309 YR AC FAIL device number 301 AT AC RESTORE device number 301 AR BOX TAMPER device number 137 TA BOX TAMPER RESTORE device number 137 TR KEYPAD TAMPER 137 TA KEYPAD PANIC audible 120 PA KEYPAD...

Page 72: ...larm 17 WA Water Alarm 18 QA Emergency Alarm 19 SA Sprinkler Alarm 20 ZA Freeze Alarm 21 KH High Temp Alarm 22 FA Manual Fire Alarm The NX 8E has the ability to report Ademco Contact ID transmissions...

Page 73: ...16 Zone 113 Switches 2 3 4 on 102 Zone 25 Switches 1 2 on 17 Zone 121 Switches 1 2 3 4 on 103 Zone 33 Switch 3 on 18 Zone 129 Switch 5 on 104 Zone 41 Switches 1 3 on 19 Zone 137 Switches 1 5 on 105 Zo...

Page 74: ...6 46 1 86 B 126 6 166 1 206 B 7 7 47 2 87 C 127 7 167 2 207 C 8 8 48 3 88 D 128 8 168 3 208 D 9 9 49 4 89 E 129 9 169 4 209 E 10 A 50 5 90 F 130 A 170 5 210 F 11 B 51 6 91 1 131 B 171 6 211 1 12 C 52...

Page 75: ...e equipment from the telephone line to determine if it is the customers equipment that is not functioning properly If the problem is with the device the customer shall discontinue use until it is repa...

Page 76: ...etworks in the countries marked with a check and may have interworking problems with the countries that are not checked Due to the inherent differences in the individual PSTNs certain software setting...

Page 77: ...commercial burglary installations the fire initiating circuits shall not be connected The Entry Guard feature shall be disabled Swinger Shutdown shall be disabled Group Bypassing shall be disabled De...

Page 78: ...H 1 Amp 600 mA 17 AH 1 Amp 48 hours 900 mA 51 AH 1 Amp 600 mA 34 AH 1 Amp 300 mA 17 AH 1 Amp 72 hours 600 mA 51 AH 1 Amp 400 mA 34 AH 1 Amp 200 mA 17 AH 1 Amp Calculations based on three 17 Amp batter...

Page 79: ...for the screw Diagram 2 Place the first black plastic PCB guide in the top insertion point grooved edge downward The half moon protrusion will be in the large hole It does not require force Insert one...

Page 80: ...32 to 120 degrees F LED KEYPAD Current Draw 130 mA max Zones Normal w o Sounder 55 mA Dimensions 6 4 Wide 4 0 High 1 1 Deep NX148E LCD KEYPAD Current Draw 110 mA max w o Sounder 75 mA Dimensions 6 4...