![background image](http://html1.mh-extra.com/html/omron/r88d-1sn01h-ect/r88d-1sn01h-ect_user-manual_742796399.webp)
7 - 33
7 Applied Functions
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User’s Manual (I586)
7-9
Sof
t S
tart
7
7-9
-3 V
elocity C
ommand F
irst-
order
Lag Filter
Precautions for Correct Use
Do not set the Acceleration Time and the Deceleration Time when the position loop structure
with a host controller is used.
The command first-order lag filter is an IIR filter for velocity commands.
7-9-3
Velocity Command First-order Lag Filter
Vc × 0.632
(s)
Vc × 0.368
Time
Velocity command [r/min]
Target velocity
Target velocity
Target velocity
Velocity command
before filter process
Velocity command
after filter process
1/(2
π
× Filter Cutoff Frequency)
Summary of Contents for R88D-1SN01H-ECT
Page 827: ......