![background image](http://html1.mh-extra.com/html/omron/r88d-1sn01h-ect/r88d-1sn01h-ect_user-manual_742796712.webp)
Appendices
A - 64
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User’s Manual (I586)
z
Bit Description of Subindex 01 hex
z
Bit Description of Subindex 02 hex
• This object gives and resets an error of the safety function.
• You can use this function by mapping this object to the safety process data.
• If you map this object to the SDO communications or normal PDOs, the written value will be ignored.
z
Description of Reading and Writing
• This object gives the STO status and issues the STO command.
• You can use this function by mapping this object to the safety process data.
• If you map this object to the SDO communications or normal PDOs, the written value will be ignored.
Bit
Description
1
Gives the STO status.
0: Normal status
1: STO status
7
Gives the error status of the safety
function.
0: No error
1: Error detected
Bit
Description
7
Gives the safety connection status.
0: Without safety connection
1: With safety connection
Index
(hex)
Sub-
index
(hex)
Object name
Setting
range
Unit
Default
setting
Data
attri-
bute
Size
Access
PDO
map
Com-
plete
access
Modes of
operation
6632
---
error acknowl-
edge
0 to 1
---
0
---
1 bit
(BOOL)
W
RxPDO,
TxPDO
Not possi-
ble
---
Access
Description
Read
Gives an error of the safety function.
0: No error
1: Error detected (STO internal circuit error
detection)
Write
Resets an error of the safety function.
From 0 to 1: Error reset
Index
(hex)
Sub-
index
(hex)
Object name
Setting
range
Unit
Default
setting
Data
attri-
bute
Size
Access
PDO
map
Com-
plete
access
Modes of
operation
6640
---
STO command
0 to 1
---
0
---
1 bit
(BOOL)
W
RxPDO,
TxPDO
Not possi-
ble
---
Summary of Contents for R88D-1SN01H-ECT