7 Applied Functions
7 - 14
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User’s Manual (I586)
z
Remote Output (R-OUT1 to R-OUT3)
• Remote Output 1 (R-OUT1) turns ON and OFF according to the value of bit 16 in the
Digital out-
puts
(60FE hex).
• Remote Output 2 (R-OUT2) turns ON and OFF according to the value of bit 17 in the
Digital out-
puts
(60FE hex).
• Remote Output 3 (R-OUT3) turns ON and OFF according to the value of bit 18 in the
Digital out-
puts
(60FE hex).
z
Zone Notification Output (ZONE1 and ZONE2)
• Zone Notification Output 1 turns ON when the present position is within the range between
Lower
Limit
(3B40-01 hex) and
Upper Limit
(3B40-02 hex) of
Zone Notification 1
.
• Zone Notification Output 2 turns ON when the present position is within the range between
Lower
Limit
(3B41-01 hex) and
Upper Limit
(3B41-02 hex) of
Zone Notification 2
.
• The Zone Notification Output is performed when home is defined. This output is always OFF
when home is undefined.
z
Distribution Completed Output (DEN)
• This output turns ON when the command position inside the Servo Drive reaches the target posi-
tion.
Time
Position
Present position
Zone Notification
Upper limit
Lower limit
Zone Notification Output
ON
OFF
OFF
OFF
ON