SAFETY, ENVIRONMENTAL, AND REGULATORY INFORMATION

NI cDAQ

-9132

NI CompactDAQ Four-Slot Controller

This document includes compliance precautions and connection information for the
NI cDAQ-9132.

Note

 

The guidelines in this document are specific to the NI cDAQ-9132. The other

components in the system might not meet the same ratings. Refer to the
documentation for each component in the system to determine the safety and EMC
guidelines for the entire system.

Safety Guidelines

Caution

 

Do not operate the NI cDAQ-9132 in a manner not specified in this user

manual. Product misuse can result in a hazard. You can compromise the safety
protection built into the product if the product is damaged in any way. If the product
is damaged, return it to National Instruments for repair.

Note

 

Because some C Series modules may have more stringent certification

standards than the NI cDAQ-9132, the combined system may be limited by
individual component restrictions. Refer to the 

NI cDAQ-9132 Specifications

 for

more details.

Hot Surface

 

This icon denotes that the component may be hot. Touching this

component may result in bodily injury.

Safety Voltages

Connect only voltages that are below these limits.

V1 terminal to C terminal

30 VDC maximum, Measurement Category I

V2 terminal to C terminal

30 VDC maximum, Measurement Category I

Chassis ground to C terminal

30 VDC maximum, Measurement Category I

Measurement Category I is for measurements performed on circuits not directly connected to
the electrical distribution system referred to as 

MAINS

 voltage. MAINS is a hazardous live

electrical supply system that powers equipment. This category is for measurements of voltages
from specially protected secondary circuits. Such voltage measurements include signal levels,
special equipment, limited-energy parts of equipment, circuits powered by regulated low-
voltage sources, and electronics.

Summary of Contents for cDAQ-9132

Page 1: ...ification standards than the NI cDAQ 9132 the combined system may be limited by individual component restrictions Refer to the NI cDAQ 9132 Specifications for more details Hot Surface This icon denote...

Page 2: ...ess power has been switched off or the area is known to be nonhazardous Caution Do not remove modules unless power has been switched off or the area is known to be nonhazardous Caution Substitution of...

Page 3: ...e system shall be mounted in an ATEX IECEx certified enclosure with a minimum ingress protection rating of at least IP54 as defined in IEC EN 60079 15 Caution The enclosure must have a door or cover a...

Page 4: ...ut V1 and a secondary power input V2 The POWER LED on the front panel identifies the power input in use When the LED is lit green V1 is in use when the LED is lit yellow V2 is in use Caution Do not co...

Page 5: ...current If the power source is connected to the power connector using long wiring with high DC resistance the voltage at the power connector may be significantly lower than the specified voltage of th...

Page 6: ...in the product documentation Furthermore any changes or modifications to the product not expressly approved by National Instruments could void your authority to operate it under your local regulatory...

Page 7: ...B Host Ports Install a noise suppression ferrite National Instruments part number 711849 01 included in the shipping kit around all external USB cables attached to the USB host ports to ensure that yo...

Page 8: ...to the NI Trademarks and Logo Guidelines at ni com trademarks for information on NI trademarks Other product and company names mentioned herein are trademarks or trade names of their respective compa...

Reviews: