![background image](http://html1.mh-extra.com/html/omron/r88d-1sn01h-ect/r88d-1sn01h-ect_user-manual_742796316.webp)
4 Configuration and Wiring
4 - 50
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User’s Manual (I586)
Normally, short-circuit B2 and B3.
When an External Regeneration Resistor is required, remove the short-circuit wire between B2 and B3,
and connect an External Regeneration Resistor between B1 and B2 as shown below.
Precautions for Correct Use
In
Regeneration
(4310 hex), set a value which is appropriate for the external regeneration
resistor that is connected. If you set a wrong value, the resistor may produce heat abnormally,
and fire or burning may result.
4-4-4
Connecting an External Regeneration Resistor
Servo Drive
B1
B2
External Regeneration
Resistor
Remove the short-circuit wire
between B2 and B3.
B3