212
Pulse Outputs
Section 5-2
Origin Search Examples
Operation
Connect a Servo Driver and execute an origin search based on the Servomo-
tor's built-in encoder phase-Z signal and a Origin Proximity Input Signal.
Conditions
• Operating mode: 1
(Uses the Servomotor encoder's phase-Z signal as the Origin Input Sig-
nal.)
• Origin search operation setting: 0
(Sets reverse mode 1. Reverses direction when the limit input signal is
input in the origin search direction.)
• Origin detection method: 0
(Reads the Origin Input Signal after the Origin Input Signal goes
OFF
→
ON
→
OFF.)
• Origin search direction: 0 (CW direction)
System Configuration
Instructions Used
ORG(889)
CW limit
detection
sensor
Origin Proximity
Input sensor
Workpiece
CCW limit
detection
sensor
Servomotor
Encoder
Servomotor Driver
Pulse output from built-in
outputs OUT0
0.00: Servomotor encoder's
phase-Z input; Origin input
0.10: Origin proximity input sensor
0.00: CW limit detection sensor
0.01: CCW limit detection sensor
Summary of Contents for CP1L - 12-2007
Page 3: ...iv...
Page 9: ...x...
Page 13: ...xiv TABLE OF CONTENTS...
Page 21: ...xxii...
Page 33: ...xxxiv Conformance to EC Directives 6...
Page 65: ...32 Function Blocks Section 1 5...
Page 428: ...395 Clock Section 6 9...
Page 429: ...396 Clock Section 6 9...
Page 523: ...488 Troubleshooting Unit Errors Section 9 4...
Page 531: ...496 Replacing User serviceable Parts Section 10 2...
Page 563: ...528 Auxiliary Area Allocations by Function Appendix C...
Page 611: ...576 Auxiliary Area Allocations by Address Appendix D...
Page 638: ...603 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 639: ...604 Connections to Serial Communications Option Boards Appendix F...
Page 669: ...634 Index...
Page 671: ...636 Revision History...