534
Auxiliary Area Allocations by Address
Appendix D
A36
07
Error Counter
Alarm Flag 1
This flag turns ON when an alarm
occurs in the error counter for
inverter positioning 1.
ON: Error
counter alarm
OFF: No error
counter alarm
---
Cleared
When
pulse out-
put to error
counter is
stopped
and abso-
lute value
of error
counter
present
value is
greater
than or
equal to
error
counter
alarm
detection
value
---
15
Inverter Posi-
tioning Output
Value Sign
Flag 1
This flag is ON when the inverter
positioning 1 output value is positive
and is OFF when it is negative.
ON: Positive
value
OFF: Nega-
tive value
---
Cleared
When
signed out-
put value is
between
FFFF
FFFF and
8000 0000
---
A38
and
A39
Present Value
of Pulse Out-
put to Inverter
1, Relative
Value
These words contain the relative
value of the internal pulse output
when pulses are being output to the
error counter for inverter positioning
1.
Data range: 8000 0000 to 7FFF
FFFF hex (
−
2,147,483,648 to
2,147,483,647)
A38 contains the leftmost 4 digits
and A39 contains the rightmost 4
digits.
---
---
Cleared
Every error
counter 1
cycle
---
A90 to
A93
All
User Program
Date
These words contain in BCD the
date and time that the user program
was last overwritten.
A90.00 to A90.07:
Seconds (00 to 59)
A90.08 to A90.15:
Minutes (00 to 59)
A91.00 to A91.07: Hour (00 to 23)
A91.08 to A91.15:
Day of month (01 to 31)
A92.00 to A92.07: Month (01 to 12)
A92.08 to A92.15: Year (00 to 99)
A93.00 to A93.07: Day of the week
(00: Sunday, 01: Monday, 02: Tues-
day, 03: Wednesday, 04: Thursday,
05: Friday, 06: Saturday)
---
Retained
Retained ---
---
A94 to
A97
All
Parameter
Date
These words contain in BCD the
date and time that the parameters
were last overwritten.
The format is the same as above.
---
Retained
Retained ---
---
Address
Name
Function
Settings
Status
after
mode
change
Status
at star-
tup
Write
timing
Related
flags, set-
tings
Words
Bits
Summary of Contents for CP1L - 12-2007
Page 3: ...iv...
Page 9: ...x...
Page 13: ...xiv TABLE OF CONTENTS...
Page 21: ...xxii...
Page 33: ...xxxiv Conformance to EC Directives 6...
Page 65: ...32 Function Blocks Section 1 5...
Page 428: ...395 Clock Section 6 9...
Page 429: ...396 Clock Section 6 9...
Page 523: ...488 Troubleshooting Unit Errors Section 9 4...
Page 531: ...496 Replacing User serviceable Parts Section 10 2...
Page 563: ...528 Auxiliary Area Allocations by Function Appendix C...
Page 611: ...576 Auxiliary Area Allocations by Address Appendix D...
Page 638: ...603 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 639: ...604 Connections to Serial Communications Option Boards Appendix F...
Page 669: ...634 Index...
Page 671: ...636 Revision History...