![background image](http://html1.mh-extra.com/html/omron/cp1l-12-2007/cp1l-12-2007_operation-manual_742083584.webp)
549
Auxiliary Area Allocations by Address
Appendix D
A342
A342.03 Memory Cas-
sette Write
Flag
ON when data is being written to the
Memory Cassette.
OFF: Not writ-
ing
ON: Writing
Retained
Cleared
---
---
A342.04 Memory Cas-
sette Read
Flag
ON when data is being read from the
Memory Cassette.
OFF: Not
reading
ON: Reading
Retained
Cleared
---
---
A342.05 Memory Cas-
sette Verify
Flag
ON when data is being compared
with data on the Memory Cassette.
OFF: Not veri-
fying
ON: Verifying
Retained
Cleared
---
---
A342.07 Memory Cas-
sette Initializa-
tion Error Flag
ON when an error occurs in initializ-
ing the Memory Cassette.
OFF the next time the Memory Cas-
sette is accessed normally (initial-
ized, written, read, or compared).
OFF: No error
ON: Error
Retained
Cleared
---
---
A342.08 Memory Cas-
sette Write
Error Flag
ON when an error occurs in writing
the Memory Cassette.
OFF the next time the Memory Cas-
sette is accessed normally (initial-
ized, written, read, or compared).
OFF: No error
ON: Error
Retained
Cleared
---
---
A342.10 Memory Cas-
sette Read
Error Flag
ON when an error occurs in reading
the Memory Cassette.
OFF the next time the Memory Cas-
sette is accessed normally (initial-
ized, written, read, or compared).
OFF: No error
ON: Error
Retained
Cleared
---
---
A342.12 Memory Cas-
sette Mis-
match Flag
ON the data in the CPU Unit is not
the same as the data in the Memory
Cassette when a verification opera-
tion is performed.
OFF the next time the Memory Cas-
sette is accessed normally (initial-
ized, written, read, or compared).
OFF: Match
ON: Mis-
match
Retained
Cleared
---
---
A342.13 Memory Cas-
sette Access
Flag
ON when the Memory Cassette is
being accessed.
OFF when access is completed.
OFF: Not
being
accessed
ON: Being
accessed
Cleared
---
---
A342.15 Memory Cas-
sette Flag
ON when a Memory Cassette is
mounted.
OFF when a Memory Cassette is not
mounted.
OFF: No
Memory Cas-
sette
ON: Memory
Cassette
mounted
Retained
Cleared
---
---
A345
A345.00 FB Program
Data Flag
Turns ON if the FB program memory
contains FB program data.
OFF: No data
ON: Data
present
Retained
Cleared
Download-
ing pro-
grams from
CX-Pro-
grammer
or Memory
Cassette
or clearing
VM
---
A345.01 Program Index
File Flag
Turns ON when the comment mem-
ory contains a program index file.
OFF: No file
ON: File
present
Download-
ing pro-
grams from
CX-Pro-
grammer
or Memory
Cassette
A345.02 Comment File
Flag
Turns ON when the comment mem-
ory contains a comment file.
OFF: No file
ON: File
present
A345.03 Symbol Table
File Flag
Turns ON when the comment mem-
ory contains a symbol table file.
OFF: No file
ON: File
present
A345.04 DM Initial Val-
ues Flag
ON when DM initial values are stored
in the flash memory.
OFF: No val-
ues stored
ON: Values
stored
---
---
---
---
Address
Name
Function
Settings
Status
after
mode
change
Status
at star-
tup
Write
timing
Related
flags, set-
tings
Words
Bits
Summary of Contents for CP1L - 12-2007
Page 3: ...iv...
Page 9: ...x...
Page 13: ...xiv TABLE OF CONTENTS...
Page 21: ...xxii...
Page 33: ...xxxiv Conformance to EC Directives 6...
Page 65: ...32 Function Blocks Section 1 5...
Page 428: ...395 Clock Section 6 9...
Page 429: ...396 Clock Section 6 9...
Page 523: ...488 Troubleshooting Unit Errors Section 9 4...
Page 531: ...496 Replacing User serviceable Parts Section 10 2...
Page 563: ...528 Auxiliary Area Allocations by Function Appendix C...
Page 611: ...576 Auxiliary Area Allocations by Address Appendix D...
Page 638: ...603 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 639: ...604 Connections to Serial Communications Option Boards Appendix F...
Page 669: ...634 Index...
Page 671: ...636 Revision History...