BIC 1I12-P2A25-M30MI1-BPX05-110 

 

BIC 2I12-P2A25-M30MI1-BPX03-010 

 

 

User´s Guide

 

 

 

Содержание BIC 1I12-P2A25-M30MI1-BPX05-110

Страница 1: ...BIC 1I12 P2A25 M30MI1 BPX05 110 BIC 2I12 P2A25 M30MI1 BPX03 010 User s Guide...

Страница 2: ...iew 4 Topology 4 Block Diagram 4 Base Display 4 Timing Diagram 5 3 Installation 6 Transmission Distance 6 Mutual Interference 6 Offset 6 Installation in Metal 6 Angular Offset 7 Commissioning 7 InZone...

Страница 3: ...manufacturer are rendered invalid by damages due to unauthorized tampering improper use use installation handling contrary to the regulations in this user guide User Responsibilities This equipment is...

Страница 4: ...by the BIC system may pose a health hazard to persons with medical aids such as a pacemaker The minimum distance for such persons is 15 mm The operator is responsible for ensuring that this minimum d...

Страница 5: ...se and Remote The inductive coupling between Base and Remote is displayed via the signal In Zone at the LED The signal In Zone will be transmitted to the control unit The inductive coupler system has...

Страница 6: ...Diagram REMOTE Switch S S closed S open BASE DataValid BASE Signal t t rotate DAV trotate depends on the rotating speed Customer s specification maximum rotating speed of 44 rpm and mounting position...

Страница 7: ...s must be observed to avoid mutual influence between neighboring base and remote A mm 40 mm Offset Permitted distances axial offset X mm Y mm 3 10 Installation in Metal Attention Device damage due to...

Страница 8: ...y with remote coupler BIC 2I12 P2A25 M30MI1 BPX03 010 Commissioning is only possible after complete assembly of an entire transmission chain between base and remote For safety reasons components must...

Страница 9: ...00 g Operating temperature 40 C 50 C Storage temperature 40 C 70 C Installation type Not flush Electrical Data Operating voltage 24 V 10 Current drain max 300 mA No load current max 100 mA Overload pr...

Страница 10: ...60 g Operating temperature 40 C 50 C Storage temperature 40 C 70 C Installation type Not flush Electrical Data Operational 2 5 ms Switching frequency max 40 Hz Short circuit protection Yes No of digit...

Страница 11: ...2A25 M30MI1 BPX05 110 Base BIC 2I12 P2A25 M30MI1 BPX03 010 Remote www balluff com 10 5 Attachment Ordering Information Product Name Item Number BIC 1I12 P2A25 M30MI1 BPX05 110 Base BIC007Z BIC 2I12 P2...

Страница 12: ...w balluff com Balluff GmbH Schurwaldstrasse 9 D 73765 Neuhausen a d F Germany Phone 49 7158 173 0 Fax 49 7158 5010 balluff balluff de No 939250 726 EN 02 130491 Edition K20 Replaces Edition D18 Subjec...