178
Pulse Outputs
Section 5-2
5-2-2
Pulse Output Specifications
Specifications
Pulse Output Modes
There are two pulse output modes. In independent mode the number of out-
put pulses is specified and in continuous mode the number of output pulses is
not specified.
Item
Specifications
Output mode
Continuous mode (for speed control) or independent mode (for position control)
Positioning (independent mode)
instructions
PULS(886) and SPED(885), PULS(886) and ACC(888), or PLS2(887)
Speed control (continuous mode)
instructions
SPED(885) or ACC(888)
Origin (origin search and origin
return) instructions
ORG(889)
Output frequency
Pulse outputs 0, 1: 1 Hz to 100 kHz (1 Hz units)
(J models: 1 Hz to 20 kHz (1 Hz units))
Frequency acceleration and decel-
eration rates
Set in 1 Hz units for acceleration/deceleration rates from 1 Hz to 65,635 Hz (every 4
ms). The acceleration and deceleration rates can be set independently only with
PLS2(887).
Changing SVs during instruction
execution
The target frequency, acceleration/deceleration rate, and target position can be
changed.
Duty factor
Fixed at 50%
Pulse output method
CW/CCW inputs or Pulse + direction inputs
The method is selected with an instruction operand. The same method must be used
for pulse outputs 0 and 1.
Number of output pulses
Relative coordinates: 0000 0000 to 7FFF FFFF hex
(Each direction accelerating or decelerating: 2,147,483,647)
Absolute coordinates: 8000 0000 to 7FFF FFFF hex
(
−
2147483648 to 2147483647)
Pulse output PV's relative/absolute
coordinate specification
Absolute coordinates are specified automatically when the origin location has been
determined by setting the pulse output PV with INI(880) or performing an origin
search with ORG(889). Relative coordinates are used when the origin location is
undetermined.
Relative pulse specification/
Absolute pulse specification
The pulse type can be specified with an operand in PULS(886) or PLS2(887).
Note
The absolute pulse specification can be used when absolute coordinates are specified for
the pulse output PV, i.e. the origin location has been determined.
The absolute pulse specification cannot be used when relative coordinates are specified,
i.e. the origin location is undetermined. An instruction error will occur.
Pulse output PV's storage location The following Auxiliary Area words contain the pulse output PVs:
Pulse output 0: A277 (leftmost 4 digits) and A276 (rightmost 4 digits)
Pulse output 1: A279 (leftmost 4 digits) and A278 (rightmost 4 digits)
The PVs are refreshed during regular I/O refreshing.
Acceleration/deceleration curve
specification
Trapezoidal or S-curve acceleration/deceleration
Mode
Description
Independent mode
This mode is used for positioning.
Operation stops automatically when the preset num-
ber of pulses has been output. It is also possible to
stop the pulse output early with INI(880).
Continuous mode
This mode is used for speed control.
The pulse output will continue until it is stopped by
executing another instruction or switching the PLC to
PROGRAM mode.
Summary of Contents for CP1L - 12-2007
Page 3: ...iv...
Page 9: ...x...
Page 13: ...xiv TABLE OF CONTENTS...
Page 21: ...xxii...
Page 33: ...xxxiv Conformance to EC Directives 6...
Page 65: ...32 Function Blocks Section 1 5...
Page 428: ...395 Clock Section 6 9...
Page 429: ...396 Clock Section 6 9...
Page 523: ...488 Troubleshooting Unit Errors Section 9 4...
Page 531: ...496 Replacing User serviceable Parts Section 10 2...
Page 563: ...528 Auxiliary Area Allocations by Function Appendix C...
Page 611: ...576 Auxiliary Area Allocations by Address Appendix D...
Page 638: ...603 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 639: ...604 Connections to Serial Communications Option Boards Appendix F...
Page 669: ...634 Index...
Page 671: ...636 Revision History...