Section 7-6
Operating Procedure
Connecting the
CompoBus/S I/O Link Unit
CompoBus/S I/O Link Units are connected to the CP1L CPU Unit. Up to three
Units can be connected, including any other Expansion Units and Expansion
I/O Units that are also connected. The Units can be connected in any order
from the CPU Unit.
I/O Allocation
I/O words are allocated to the CompoBus/S I/O Link Unit in the same way as
to other Expansion Units and Expansion I/O Units, i.e., the next available input
and output words are allocated. As shown below, when “m” is the last allo-
cated input word and “n” is the last allocated output word, the CompoBus/S I/
O Link Unit is allocated “m+1” as its input word and “n+1” as its output word.
In the following example, a CompoBus/S I/O Link Unit is connected as the first
Unit after the CP1L CPU Unit.
Connect the Unit.
Determine the node
address of the
CompoBus/S I/O Link Unit
and set the DIP switch.
Wire the CompoBus/S
transmission path.
•
Connect the CompoBus/S I/O Link Unit.
•
The node number should be a unique number between
0 and 15.
•
Use the DIP switch to set the CompoBus/S I/O Link
Unit fs node number, communications mode, and the
status of output data when a communications error
occurs.
•
Connect the CompoBus/S I/O Link Unit to a
CompoBus/S transmission path.
BD L NC( BS-) N C
BD H
NC( BS+)
S
COMM
ERR
ON
1 2
3
4 5
6
No.
SRT21
EXP
SYSMAC
CP1L
L1
L2/N
COM
01
03
05
07
09
11
01
03
05
07
09
11
00
02
04
06
08
10
00
02
04
06
08
10
00
01
02
03
04
06
00
01
03
04
06
COM
COM
COM
COM
05
07
COM
02
COM
05
07
IN
OUT
CPU Unit
CompoBus/S I/O Link Unit
Word m+1
CompoBus/S I/O Link Unit
8 inputs
8 outputs
Word n+1
CP1L
CPU Unit
CompoBus/S
I/O LInk Unit
Input words
Output words
CIO 0
CIO 1
CIO 100
CIO 101
CIO 2
CIO 102
Summary of Contents for CP1L - 12-2007
Page 3: ...iv...
Page 9: ...x...
Page 13: ...xiv TABLE OF CONTENTS...
Page 21: ...xxii...
Page 33: ...xxxiv Conformance to EC Directives 6...
Page 65: ...32 Function Blocks Section 1 5...
Page 428: ...395 Clock Section 6 9...
Page 429: ...396 Clock Section 6 9...
Page 523: ...488 Troubleshooting Unit Errors Section 9 4...
Page 531: ...496 Replacing User serviceable Parts Section 10 2...
Page 563: ...528 Auxiliary Area Allocations by Function Appendix C...
Page 611: ...576 Auxiliary Area Allocations by Address Appendix D...
Page 638: ...603 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 639: ...604 Connections to Serial Communications Option Boards Appendix F...
Page 669: ...634 Index...
Page 671: ...636 Revision History...