290
Inverter Positioning
Section 5-3
A33
00 to 15 Inverter frequency
command value
(0.01-Hz increments,
unsigned)
Note
Set the Power
Supply Fre-
quency for
One Motor
Revolution per
Second, Num-
ber of
Encoder
Pulses for
One Motor
Revolution,
and Error
Counter Cycle
in the PLC
Setup before
using this
value.
0000 to FFFF hex
(0.00 to
655.35 Hz)
Cleared to zero at following times:
• When power to CPU Unit is turned ON
• At start of operation
• When an error counter error occurs
Updated at following times:
Cyclically according to error counter
cycle
These words con-
tain the automati-
cally calculated
frequency com-
mand value for the
inverter. (This value
is normally used.)
For example, if the
frequency setting
unit of the inverter
is 0.01 Hz, this
value can be used
as it in serial com-
munications with
the inverter. When
converting to an
analog output (0 to
5 V, 1 to 5 V, 0 to 10
V, 0 to 20 mA, or 4
to 20 mA), this
value can be used
to simplify the con-
version.
This value is used
when signed data
is not required, i.e.,
when using com-
munications or nor-
mal I/O to specify
the direction.
A34
00 to 15 Lower 4 digits of
present value of
signed output value
(output value =
present value of
error counter
×
error
counter cycle (s)
×
gain)
Note
The maxi-
mum and min-
imum output
values are
applied.
8000 0000 to 7FFF
FFFF hex
(
−
214,748,348 to
214,748,347)
Cleared to zero at following times:
• When power to CPU Unit is turned ON
• At start of operation
• When an error counter error occurs
Updated at following times:
• Cyclically according to error counter
cycle
This value can be
used when not
using automatic
frequency com-
mand calculations
and instead to con-
vert the output
value provided
here in the user
program for output
to the inverter.
This value is used
when signed data
is required, i.e.,
when outputting
the frequency com-
mand with an ana-
log output from
−
10
to 10 V.
A35
00 to 15 Upper 4 digits of
present value of
signed output value
(output value =
present value of
error counter
×
error
counter cycle (s)
×
gain)
Note
The maxi-
mum and min-
imum output
values are
applied.
Word
Bits
Function
Data range
Refresh timing
Application
examples
Summary of Contents for CP1L - 12-2007
Page 3: ...iv...
Page 9: ...x...
Page 13: ...xiv TABLE OF CONTENTS...
Page 21: ...xxii...
Page 33: ...xxxiv Conformance to EC Directives 6...
Page 65: ...32 Function Blocks Section 1 5...
Page 428: ...395 Clock Section 6 9...
Page 429: ...396 Clock Section 6 9...
Page 523: ...488 Troubleshooting Unit Errors Section 9 4...
Page 531: ...496 Replacing User serviceable Parts Section 10 2...
Page 563: ...528 Auxiliary Area Allocations by Function Appendix C...
Page 611: ...576 Auxiliary Area Allocations by Address Appendix D...
Page 638: ...603 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 639: ...604 Connections to Serial Communications Option Boards Appendix F...
Page 669: ...634 Index...
Page 671: ...636 Revision History...