Origin Detection Method 1: Origin Proximity Input Signal Reversal Not
Required
Origin Detection Method 2: Origin Proximity Input Signal Reversal Not
Used
Origin Search Operating
Mode and Origin
Detection Method Settings
The following examples explain how the operation patterns are affected by the
origin search operation and origin detection method settings.
These examples have a CW origin search direction. (The search direction and
limit input signal direction would be different for an origin search in the CCW
direction.)
1
1
0
0
CCW
CW
Origin Proximity
Input Signal
Origin Input
Signal
Pulse output
Deceleration starts when
Origin Proximity Input
Signal goes OFF
→
ON.
After the Origin Proximity Input Signal has gone
from OFF
→
ON
→
OFF, the motor is stopped when
the Origin Input Signal goes OFF
→
ON.
Initial
speed
Acceleration
High speed for
origin search
Deceler-
ation
Proximity speed for origin search
Start when
ORG(889) is
executed.
Stop
1
0
Origin Input
Signal
Pulse output
Deceleration starts when
Origin Proximity Input
Signal goes OFF
→
ON.
Initial
speed
Acceleration
Proximity speed
for origin search
Start when
ORG(889) is
executed.
Stop
Summary of Contents for CP1L - 12-2007
Page 3: ...iv...
Page 9: ...x...
Page 13: ...xiv TABLE OF CONTENTS...
Page 21: ...xxii...
Page 33: ...xxxiv Conformance to EC Directives 6...
Page 65: ...32 Function Blocks Section 1 5...
Page 428: ...395 Clock Section 6 9...
Page 429: ...396 Clock Section 6 9...
Page 523: ...488 Troubleshooting Unit Errors Section 9 4...
Page 531: ...496 Replacing User serviceable Parts Section 10 2...
Page 563: ...528 Auxiliary Area Allocations by Function Appendix C...
Page 611: ...576 Auxiliary Area Allocations by Address Appendix D...
Page 638: ...603 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 639: ...604 Connections to Serial Communications Option Boards Appendix F...
Page 669: ...634 Index...
Page 671: ...636 Revision History...