286
Inverter Positioning
Section 5-3
Use the following for inverter positioning status and the workpiece position.
Word
Bits
Function
Data range
Refresh timing
Application
examples
A26
00
Operation Command
Flag
ON: Operation
command exe-
cuted.
OFF: Stop com-
mand executed.
Turned ON at following times:
• When inverter positioning is started
Turned OFF at following times:
• When power to CPU Unit is turned ON
• At start of operation
• When CPU Unit operation stops
• When inverter positioning is stopped
using INI instruction
This flag is used as
a NO input condi-
tion when calculat-
ing the frequency
command value in
the user program. It
is also used as a
NC input condition
when clearing the
frequency com-
mand value to zero.
01
Forward Operation
Command Flag
ON: Forward com-
mand in progress
OFF: Reverse
command in
progress or
stopped
Turned ON at following times:
• When error counter present value is
greater than 0 (i.e., positive)
Turned OFF at following times:
• When error counter present value is
less than 0 (i.e., negative) or zero
• When power to CPU Unit is turned ON
• When CPU Unit operation starts
• When CPU Unit operation stops
This flag is used as
a NO input condi-
tion when output-
ting a forward
operation com-
mand to the
inverter from the
user program
It is also used as a
NC input condition
when outputting a
reverse command
to the inverter.
02
Reverse Operation
Command Flag
ON: Reverse com-
mand in progress
OFF: Forward
command in
progress or
stopped
Turned ON at following times:
• When error counter present value is
less than 0 (i.e., negative)
Turned OFF at following times:
• When error counter present value is
greater than 0 (i.e., positive) or zero
• When power to CPU Unit is turned ON
• When CPU Unit operation starts
• When CPU Unit operation stops
This flag is used as
a NO input condi-
tion when output-
ting a reverse
operation com-
mand to the
inverter from the
user program
It is also used as a
NC input condition
when outputting a
forward command
to the inverter.
Summary of Contents for CP1L - 12-2007
Page 3: ...iv...
Page 9: ...x...
Page 13: ...xiv TABLE OF CONTENTS...
Page 21: ...xxii...
Page 33: ...xxxiv Conformance to EC Directives 6...
Page 65: ...32 Function Blocks Section 1 5...
Page 428: ...395 Clock Section 6 9...
Page 429: ...396 Clock Section 6 9...
Page 523: ...488 Troubleshooting Unit Errors Section 9 4...
Page 531: ...496 Replacing User serviceable Parts Section 10 2...
Page 563: ...528 Auxiliary Area Allocations by Function Appendix C...
Page 611: ...576 Auxiliary Area Allocations by Address Appendix D...
Page 638: ...603 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 639: ...604 Connections to Serial Communications Option Boards Appendix F...
Page 669: ...634 Index...
Page 671: ...636 Revision History...