Auxiliary Area Allocations by Address
Appendix D
A540
A540.10 Pulse Out-
put 0 Posi-
tioning
Completed
Signal
This is the positioning completed
input signal used in the origin search
for pulse output 0. The input signal
from the servo driver is output to this
bit from the ladder program to enable
using the signal.
---
Retained
Cleared
---
A541
A541.00 Pulse Out-
put 1 Reset
Bit
The pulse output 1 PV (contained in
A278 and A279) will be cleared when
this bit is turned ON.
---
Retained
Cleared
---
A278 and
A279
A541.08 Pulse Out-
put 1 CW
Limit Input
Signal Flag
This is the CW limit input signal for
pulse output 1, which is used in the
origin search. To use this signal,
write the input from the actual sensor
as an input condition in the ladder
program and output the result to this
flag.
---
Retained
Cleared
---
---
A541.09 Pulse Out-
put 1 CCW
Limit Input
Signal Flag
This is the CCW limit input signal for
pulse output 1, which is used in the
origin search. To use this signal,
write the input from the actual sensor
as an input condition in the ladder
program and output the result to this
flag.
---
Retained
Cleared
---
---
A541.10 Pulse Out-
put 1 Posi-
tioning
Completed
Signal
This is the positioning completed
input signal used in the origin search
for pulse output 1. The input signal
from the servo driver is output to this
bit from the ladder program to enable
using the signal.
---
Retained
Cleared
---
---
A562
A562.00 Error
Counter 0
Reset Bit
Turn ON this bit to reset the Error
Counter 0 Present Value and turn
OFF the Error Counter 0 Error Flag.
---
---
Cleared
---
---
A562.01 Error
Counter 0
Disable Bit
Turn ON this bit to hold the present
value of error counter 0.
ON: Error
counter value
held.
OFF: Error
counter value
not held.
---
Cleared
---
---
A563
A563.00 Error
Counter 1
Reset Bit
Turn ON this bit to reset the Error
Counter 1 Present Value and turn
OFF the Error Counter 0 Error Flag.
---
---
Cleared
---
---
A563.01 Error
Counter 1
Disable Bit
Turn ON this bit to hold the present
value of error counter 1.
ON: Error
counter value
held.
OFF: Error
counter value
not held.
---
Cleared
---
---
A580
A580.00
to
A580.03
FB Commu-
nications
Instruction
Retries
Automatically stores the number of
retries in the FB communications
instruction settings specified in the
PLC Setup.
0 to F hex
---
Cleared
Written at
start of
operation
A581
All
FB Commu-
nications
Instruction
Response
Monitoring
Time
Automatically stores the FB commu-
nications instruction response moni-
toring time set in the PLC Setup.
0001 to FFFF
hex (Unit: 0.1 s;
Range: 0.1 to
6553.5)
0000 hex: 2 s
---
Cleared
Written at
start of
operation
---
Addresses
Name
Function
Settings
Status
after
mode
change
Status at
startup
Write
timing
Related
Flags,
Settings
Word
Bits
Summary of Contents for CP1L - 12-2007
Page 3: ...iv...
Page 9: ...x...
Page 13: ...xiv TABLE OF CONTENTS...
Page 21: ...xxii...
Page 33: ...xxxiv Conformance to EC Directives 6...
Page 65: ...32 Function Blocks Section 1 5...
Page 428: ...395 Clock Section 6 9...
Page 429: ...396 Clock Section 6 9...
Page 523: ...488 Troubleshooting Unit Errors Section 9 4...
Page 531: ...496 Replacing User serviceable Parts Section 10 2...
Page 563: ...528 Auxiliary Area Allocations by Function Appendix C...
Page 611: ...576 Auxiliary Area Allocations by Address Appendix D...
Page 638: ...603 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 639: ...604 Connections to Serial Communications Option Boards Appendix F...
Page 669: ...634 Index...
Page 671: ...636 Revision History...