137
Timers and Counters
Section 4-9
In this example, a TR bit is used when an output is connected to a branch
point without a separate execution condition.
Note
A TR bit is not required when there are no execution conditions after the
branch point or there is an execution condition only in the last line of the
instruction block.
4-9
Timers and Counters
4-9-1
Timer Area (T)
The 4,096 timer numbers (T0000 to T4095) are shared by the TIM,
TIMX(550), TIMH(015), TIMHX(551), TMHH(540), TIMHHX(552), TTIM(087),
TTIMX(555), TIMW(813), TIMWX(816), TMHW(815), and TIMHWX(817)
instructions. Timer Completion Flags and present values (PVs) for these
instructions are accessed with the timer numbers.
The TIML(542), TIMLX(553), MTIM(543), and MTIMX(554) instructions do not
use timer numbers.
When a timer number is used in an operand that requires bit data, the timer
number accesses the Completion Flag of the timer. When a timer number is
used in an operand that requires word data, the timer number accesses the
PV of the timer. Timer Completion Flags can be used as often as necessary
as normally open and normally closed conditions and the values of timer PVs
can be read as normal word data.
The refresh method for timer PVs can be set from the CX-Programmer to
either BCD or binary.
Note
It is not recommended to use the same timer number in two timer instructions
because the timers will not operate correctly if they are timing simultaneously.
(If two or more timer instructions use the same timer number, an error will be
generated during the program check, but the timers will operate as long as the
instructions are not executed in the same cycle.)
LD
OUT
AND
OUT
LD
OUT
0.00
TR 0
0.01
0.02
TR 0
0.03
Instruction
Operand
TR0
0.00
0.01
0.02
0.03
LD
0.00
OUT
0.01
AND
OUT
0.02
0.03
LD
0.00
OUT
OUT
0.01
0.02
Instruction
Operand
Instruction
Operand
0.00
0.01
0.02
0.00
0.01
0.03
0.02
Summary of Contents for CP1L - 12-2007
Page 3: ...iv...
Page 9: ...x...
Page 13: ...xiv TABLE OF CONTENTS...
Page 21: ...xxii...
Page 33: ...xxxiv Conformance to EC Directives 6...
Page 65: ...32 Function Blocks Section 1 5...
Page 428: ...395 Clock Section 6 9...
Page 429: ...396 Clock Section 6 9...
Page 523: ...488 Troubleshooting Unit Errors Section 9 4...
Page 531: ...496 Replacing User serviceable Parts Section 10 2...
Page 563: ...528 Auxiliary Area Allocations by Function Appendix C...
Page 611: ...576 Auxiliary Area Allocations by Address Appendix D...
Page 638: ...603 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 639: ...604 Connections to Serial Communications Option Boards Appendix F...
Page 669: ...634 Index...
Page 671: ...636 Revision History...