183
Pulse Outputs
Section 5-2
CPU Units with 20, 30, or 40 I/O Points
Auxiliary Area Data Allocation
Input terminal
block
Default setting
High-speed counter operation settings
Origin search
setting
Word
Bit
CPU Units
with 40 I/O
Points
CPU Units
with 30 I/O
Points
CPU Units
with 20 I/O
Points
Single-phase
(increment pulse
input)
Two-phase
(differential phases
x4, up/down, or
pulse/direction)
CIO 0
00
Normal
input 0
Normal
input 0
Normal
input 0
High-speed counter
0 (Increment)
High-speed counter
0 (Phase A, Incre-
ment, or Count
input)
---
01
Normal
input 1
Normal
input 1
Normal
input 1
High-speed counter
1 (Increment)
High-speed counter
0 (Phase B, Decre-
ment, or Direction
input)
---
02
Normal
input 2
Normal
input 2
Normal
input 2
High-speed counter
2 (Increment)
High-speed counter
1 (Phase A, Incre-
ment, or Count
input)
---
03
Normal
input 3
Normal
input 3
Normal
input 3
High-speed counter
3 (Increment)
High-speed counter
0 (Phase B, Decre-
ment, or Direction
input)
---
04
Normal
input 4
Normal
input 4
Normal
input 4
High-speed counter
0 (Phase Z or reset
input)
High-speed counter
0 (Phase Z or reset
input)
---
05
Normal
input 5
Normal
input 5
Normal
input 5
High-speed counter
1 (Phase Z or reset
input)
High-speed counter
1 (Phase Z or reset
input)
---
06
Normal
input 6
Normal
input 6
Normal
input 6
High-speed counter
2 (Phase Z or reset
input)
---
Pulse output 0:
Origin input sig-
nal
07
Normal
input 7
Normal
input 7
Normal
input 7
High-speed counter
3 (Phase Z or reset
input)
---
Pulse output 1:
Origin input sig-
nal
08
Normal
input 8
Normal
input 8
Normal
input 8
---
---
---
09
Normal
input 9
Normal
input 9
Normal
input 9
---
---
---
10
Normal
input 10
Normal
input 10
Normal
input 10
---
---
Pulse output 0:
Origin proximity
input signal
11
Normal
input 11
Normal
input 11
Normal
input 11
---
---
Pulse output 1:
Origin proximity
input signal
CIO 1
00 to
05
Normal
input 12 to
17
Normal
input 12 to
17
---
---
---
---
06 to
11
Normal in
18 to 23
---
---
---
---
---
Function
Pulse output number
0
1
Pulse output PV storage words
PV range: 8000 0000 to 7FFF FFFF hex
(
−
2,147,483,648 to 2,147,483,647)
Leftmost 4 digits
A277
A279
Rightmost 4 digits
A276
A278
Summary of Contents for CP1L - 12-2007
Page 3: ...iv...
Page 9: ...x...
Page 13: ...xiv TABLE OF CONTENTS...
Page 21: ...xxii...
Page 33: ...xxxiv Conformance to EC Directives 6...
Page 65: ...32 Function Blocks Section 1 5...
Page 428: ...395 Clock Section 6 9...
Page 429: ...396 Clock Section 6 9...
Page 523: ...488 Troubleshooting Unit Errors Section 9 4...
Page 531: ...496 Replacing User serviceable Parts Section 10 2...
Page 563: ...528 Auxiliary Area Allocations by Function Appendix C...
Page 611: ...576 Auxiliary Area Allocations by Address Appendix D...
Page 638: ...603 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 639: ...604 Connections to Serial Communications Option Boards Appendix F...
Page 669: ...634 Index...
Page 671: ...636 Revision History...