![background image](http://html1.mh-extra.com/html/omron/cp1l-12-2007/cp1l-12-2007_operation-manual_742083223.webp)
190
Pulse Outputs
Section 5-2
Stopping a Pulse Output
Change
direction
Change the
direction dur-
ing position-
ing
PLS2(887) can be
executed during
positioning with rel-
ative pulse specifi-
cation to change to
absolute pulses and
reverse direction.
PULS(886)
↓
ACC(888)
(Indepen-
dent)
↓
PLS2(887)
• Number of
pulses
• Absolute
pulse spec-
ification
• Port
• “CW/CCW”
or “Pulse +
direction”
• Accelera-
tion rate
• Decelera-
tion rate
• Target fre-
quency
• Starting
frequency
PLS2(887)
↓
PLS2(887)
Change
pulse out-
put method
Not supported.
Operation
Example
application
Frequency changes
Description
Procedure
Instruction
Settings
Pulse
frequency
Target
frequency
Specified
number of
pulses
Change of direction at the
specified deceleration rate
Number of pulses
(position) changed
by PLS2(887)
Execution
of PLS2
(887)
Execution of
PLS2(887)
Time
Operation
Example applica-
tion
Frequency changes
Description
Procedure
Instruction
Settings
Stop pulse
output
(Number of
pulses set-
ting is not
preserved.)
Immediate stop
Stops the pulse out-
put immediately
and clears the num-
ber of output pulses
setting.
PULS(886)
↓
ACC(888) or
SPED(885)
(Indepen-
dent)
↓
INI(880)
• Stop pulse
output
PLS2(887)
↓
INI(880)
Stop pulse
output
(Number of
pulses set-
ting is not
preserved.)
Immediate stop
Stops the pulse out-
put immediately
and clears the num-
ber of output pulses
setting.
PULS(886)
↓
SPED(885)
(Indepen-
dent)
↓
SPED(885)
• Port
• Indepen-
dent
• Target fre-
quency = 0
Stop sloped
pulse out-
put
smoothly.
(Number of
pulses set-
ting is not
preserved.)
Decelerate to a
stop
Decelerates the
pulse output to a
stop.
Note
If ACC(888)
started the
operation, the
original
acceleration/
deceleration
rate will
remain in
effect.
If SPED(885)
started the
operation, the
acceleration/
deceleration
rate will be
invalid and
the pulse out-
put will stop
immediately.
PULS(886)
↓
ACC(888) or
SPED(885)
(Indepen-
dent)
↓
ACC(888)
(Indepen-
dent)
• Port
• Indepen-
dent
• Target fre-
quency = 0
PLS2(887)
↓
ACC(888)
(Indepen-
dent)
Pulse frequency
Present
frequency
Execution of
SPED(885)
Execution
of INI(880)
Time
Pulse frequency
Present frequency
Execution of
SPED(885)
Execution of
SPED(885)
Time
Pulse frequency
Present
frequency
Target
frequency = 0
Execution of
ACC(888)
Original
deceleration
rate
Time
Summary of Contents for CP1L - 12-2007
Page 3: ...iv...
Page 9: ...x...
Page 13: ...xiv TABLE OF CONTENTS...
Page 21: ...xxii...
Page 33: ...xxxiv Conformance to EC Directives 6...
Page 65: ...32 Function Blocks Section 1 5...
Page 428: ...395 Clock Section 6 9...
Page 429: ...396 Clock Section 6 9...
Page 523: ...488 Troubleshooting Unit Errors Section 9 4...
Page 531: ...496 Replacing User serviceable Parts Section 10 2...
Page 563: ...528 Auxiliary Area Allocations by Function Appendix C...
Page 611: ...576 Auxiliary Area Allocations by Address Appendix D...
Page 638: ...603 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 639: ...604 Connections to Serial Communications Option Boards Appendix F...
Page 669: ...634 Index...
Page 671: ...636 Revision History...