618
PLC Setup
Appendix G
Peripheral Service Settings
Set Time to All Events: Time Setting for Services
Built-in Input Settings
High Speed Counter Settings
Name
Default
Settings
When setting is read
by CPU Unit
Internal
address
Bits
Settings
1
Set time to all events
Default
Default
(4% of cycle time)
At start of operation
218
15
0
Use user setting.
1
1-1
Time allocated to
services
0: 0
×
0.1 ms =
0 ms
0: 0
×
0.1 ms = 0 ms
At start of operation
218
00 to
07
00 hex
:
:
255: 255
×
0.1 ms
FF hex
Name
Default
Settings
When setting is read
by CPU Unit
Internal
address
Bits
Settings
1
Use high speed counter 0
Do not use.
Do not use.
When power is turned
ON
50
12 to
15
0 hex
Use. 1
hex
1-1
Counting mode
Linear mode
Linear mode
At start of operation
50
08 to
11
0 hex
Circular mode
1 hex
1-1-1
Circular
Max.
Count
0
0
At start of operation
52 and 51
00 to
15
0000
0000 hex
:
:
4,294,967,295
FFFF
FFFF hex
1-2
Reset
Z phase, soft-
ware reset
Z phase, software reset
When power is turned
ON
50
04 to
07
0 hex
Software reset
1 hex
Z phase, software reset
(comparing)
2 hex
Software reset (compar-
ing)
3 hex
1-3
Input Setting
Differential
phase input
Differential phase input
When power is turned
ON
50
00 to
03
0 hex
Pulse + direction input
1 hex
Up/Down input
2 hex
Increment pulse input
3 hex
2
Use high speed counter 1
Do not use.
Do not use.
When power is turned
ON
53
12 to
15
0 hex
Use. 1
hex
2-1
Counting mode
Linear mode
Linear mode
At start of operation
53
08 to
11
0 hex
Circular mode
1 hex
2-1-1
Circular
Max.
Count
0
0
At start of operation
55 and 54
00 to
15
0000
0000 hex
:
:
4,294,967,295
FFFF
FFFF hex
2-2
Reset
Z phase, soft-
ware reset
Z phase, software reset
When power is turned
ON
53
04 to
07
0 hex
Software reset
1 hex
Z phase, software reset
(comparing)
2 hex
Software reset (compar-
ing)
3 hex
2-3
Input Setting
Differential
phase input
Differential phase input
When power is turned
ON
53
00 to
03
0 hex
Pulse + direction input
1 hex
Up/Down input
2 hex
Increment pulse input
3 hex
Summary of Contents for CP1L - 12-2007
Page 3: ...iv...
Page 9: ...x...
Page 13: ...xiv TABLE OF CONTENTS...
Page 21: ...xxii...
Page 33: ...xxxiv Conformance to EC Directives 6...
Page 65: ...32 Function Blocks Section 1 5...
Page 428: ...395 Clock Section 6 9...
Page 429: ...396 Clock Section 6 9...
Page 523: ...488 Troubleshooting Unit Errors Section 9 4...
Page 531: ...496 Replacing User serviceable Parts Section 10 2...
Page 563: ...528 Auxiliary Area Allocations by Function Appendix C...
Page 611: ...576 Auxiliary Area Allocations by Address Appendix D...
Page 638: ...603 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 639: ...604 Connections to Serial Communications Option Boards Appendix F...
Page 669: ...634 Index...
Page 671: ...636 Revision History...