250
Pulse Outputs
Section 5-2
Ladder Program
000000
(000000)
[Program Name: New Program1]
[Section Name: Section1]
Origin Search for X and Y Axis
0.00
Origin
Search
Switch
SET
W0.00
<W000.00>
a02 a06
000001
(000002)
W0.00
W1.14
Origin Search
start
<W001.14>
a48
W1.15
Origin
Search
completed
RSET
W0.00
<W000.00>
a02 a06
000002
(000006)
Operation 1: Positioning to A
W0.00
SET
W0.01
<W000.01>
a08 a12
000003
(000008)
W0.01
W1.00
Positioning to A
start
<W001.00>
a54
W2.00
Positioning
to A
completed
RSET
W0.01
<W000.01>
a08 a12
000004
(000012)
Operation 2: Positioning to B
W0.01
SET
W0.02
<W000.02>
a14 a18
000005
(000014)
W0.02
W1.01
Positioning to B
start
<W001.01>
a63
W2.01
Positioning
to B
completed
RSET
W0.02
<W000.02>
a14 a18
000006
(000018)
Operation 2: Positioning to A
W0.02
SET
W0.03
<W000.03>
a20 a24
000007
(000020)
W0.03
W3.00
Positioning to A
start
<W003.00>
a55
W2.00
Positioning
to A
completed
RSET
W0.03
<W000.03>
a20 a24
000008
(000024)
Operation3: Positioning to C
Summary of Contents for CP1L - 12-2007
Page 3: ...iv...
Page 9: ...x...
Page 13: ...xiv TABLE OF CONTENTS...
Page 21: ...xxii...
Page 33: ...xxxiv Conformance to EC Directives 6...
Page 65: ...32 Function Blocks Section 1 5...
Page 428: ...395 Clock Section 6 9...
Page 429: ...396 Clock Section 6 9...
Page 523: ...488 Troubleshooting Unit Errors Section 9 4...
Page 531: ...496 Replacing User serviceable Parts Section 10 2...
Page 563: ...528 Auxiliary Area Allocations by Function Appendix C...
Page 611: ...576 Auxiliary Area Allocations by Address Appendix D...
Page 638: ...603 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 639: ...604 Connections to Serial Communications Option Boards Appendix F...
Page 669: ...634 Index...
Page 671: ...636 Revision History...