![NXP Semiconductors LCP43 Series User Manual Download Page 122](http://html1.mh-extra.com/html/nxp-semiconductors/lcp43-series/lcp43-series_user-manual_1721817122.webp)
UM10503
All information provided in this document is subject to legal disclaimers.
© NXP B.V. 2012. All rights reserved.
User manual
Rev. 1.3 — 6 July 2012
122 of 1269
NXP Semiconductors
UM10503
Chapter 11: LPC43xx Clock Generation Unit (CGU)
11.6.14 BASE_OUT_CLK register
This register controls the clock output to the CLKOUT pin. All clock generator outputs can
be monitored through this pin.
28:24
CLK_SEL
Clock source selection. All other values are
reserved.
0x01
R/W
0x00
32 kHz oscillator
0x01
IRC (default)
0x02
ENET_RX_CLK
0x03
ENET_TX_CLK
0x04
GP_CLKIN
0x06
Crystal oscillator
0x08
PLL0AUDIO
0x09
PLL1
0x0C
IDIVA
0x0D
IDIVB
0x0E
IDIVC
0x0F
IDIVD
0x10
IDIVE
31:29
-
Reserved
-
-
Table 88.
BASE_M4_CLK to BASE_UART3_CLK control registers (BASE_M4_CLK to
BASE_UART3_CLK, address 0x4005 006C to 0x4005 00A8) bit description
Bit
Symbol
Value
Description
Reset
value
Access
Table 89.
BASE_OUT_CLK control register BASE_OUT_CLK, addresses 0x4005 00AC) bit
description
Bit
Symbol
Value
Description
Reset
value
Access
0
PD
Output stage power down
0
R/W
0
Output stage enabled (default)
1
power-down
10:1
-
Reserved
-
-
11
AUTOBLOCK
Block clock automatically during frequency
change
0
R/W
0
Autoblocking disabled
1
Autoblocking enabled
23:12
-
Reserved
-
-