8-83
January 24, 2017
Structure Function Principle
CLG835H
Radiator fan control module
DEF pump supply module line
Radiator fan control module
Control strategy
Water temperature: 90°C~100°C, target temperature: 95°C, PID regulation, i.e. fan begins to accelerate
when the temperature is more than 95°C, or vice versa
Torque oil temperature: 105°C~110°C, linear adjustment, i.e. fan operates at the minimum speed when
the temperature is not more than 105°C and other temperatures are not in the adjustable range; fan
operates at the maximum speed when the temperature is more than 110°C; when the temperature is
between 105°C~110°C, an corresponding speed can be achieved through linear scale calculation.
Air-air intercooler: temperature control node: 40,Fmin; 55,F80%; 70,80%; 75,Fmax;
Electrical schematic diagram
P18E00146
P18E00147
Torque converter oil
temperature signal
Air-air intercooler (spare)
Water temperature (spare)
Proportional output
Hydraulic oil temperature signal
Direction-changing output
Auto reverse rotating signal
Manual reverse rotating signal
Summary of Contents for CLG835H
Page 2: ......
Page 4: ...Contents January 24 2017 CLG835H...
Page 6: ...1 2 General Information January 24 2017 CLG835H...
Page 38: ...1 34 Machine Inspection Table January 24 2017 CLG835H...
Page 156: ...3 2 Power Train System January 24 2017 CLG835H...
Page 214: ...3 2 Power Train System January 24 2017 CLG835H...
Page 272: ...3 60 Testing and adjustment January 24 2017 Power Train Test CLG835H...
Page 276: ...4 4 Hydraulic System January 24 2017 CLG835H...
Page 552: ...6 2 Driver s Cab System January 24 2017 CLG835H...
Page 608: ...7 2 Structure January 24 2017 CLG835H...
Page 662: ...8 4 Electrical System January 24 2017 CLG835H...
Page 677: ...8 19 January 24 2017 Structure Function Principle CLG835H Power System P18E00014...