8-75
January 24, 2017
Structure Function Principle
CLG835H
Lighting system
Function of backup alarm
If the DW-3 gear selector is shifted to gear R, #588 outputs a high level, and the backup alarm relay
enabled. The exploded electrical schematic as follows:
Power cut-off function
The power shutoff consists of parking clutch shutoff and service clutch shutoff, both of which shut off the
powers at gear I and II of the transmission. The parking power cutoff system is started once the stop
brake switch is pulled up, as shown below:
If the clutch on/off switch is turned on, the service clutch shutoff will start through press the brake pedal
during the service, schematics as follows:
P18E00128
P18E00129
P18E00130
Summary of Contents for CLG835H
Page 2: ......
Page 4: ...Contents January 24 2017 CLG835H...
Page 6: ...1 2 General Information January 24 2017 CLG835H...
Page 38: ...1 34 Machine Inspection Table January 24 2017 CLG835H...
Page 156: ...3 2 Power Train System January 24 2017 CLG835H...
Page 214: ...3 2 Power Train System January 24 2017 CLG835H...
Page 272: ...3 60 Testing and adjustment January 24 2017 Power Train Test CLG835H...
Page 276: ...4 4 Hydraulic System January 24 2017 CLG835H...
Page 552: ...6 2 Driver s Cab System January 24 2017 CLG835H...
Page 608: ...7 2 Structure January 24 2017 CLG835H...
Page 662: ...8 4 Electrical System January 24 2017 CLG835H...
Page 677: ...8 19 January 24 2017 Structure Function Principle CLG835H Power System P18E00014...