5-3
January 24, 2017
Basic Information
CLG835H
Safety
Basic Information
Safety
Drain refrigerant in air conditioning system as required in Release (recover) refrigerant in air conditioning
system before removing compressor, condenser, reservoir, pressure switch, air conditioner coils, etc.
Seal up the removed pipe joints through a reliable method to prevent moisture in the air from entering air
conditioning system.
Universal tool, tooling list
If liquid refrigerant splashing into eyes may lead to blind; and spraying on the skin may cause
frostbite. In addition, the container for storing refrigerant can neither be exposed to ambient tem-
perature above 50°C or placed near a heat radiating device or object, nor be exposed to direct
sunlight. In this case, the temperature of the refrigerant easily rises to cause increase in pressure
in the container. When the pressure reaches high enough, the container may have leakage or
explosion.
The refrigerant itself is non-toxic, but it cannot be in direct contact with open flames or heated
metal, otherwise toxic gases will be produced.
In order to avoid the injury from refrigerant, the goggles and gloves should be worn and open fire
or smoking is prohibited.
Specifications
Main functions
10# Open-end wrench
It is used for removal and installation of captive bolts of the pipeline, joint box and
cover plate
13# Open-end wrench
It is used for removal and installation of captive bolts (nuts) of the compressor
14# Open-end wrench
It is used for removal and installation of hold-down nuts (screw rods) of tension pul-
ley
19# Open-end wrench
It is used for removal and installation of air conditioning pipe joint in the evaporator
assembly
21# Open-end wrench
It is used for removal and installation of air conditioning pipe joint in the evaporator
assembly
24# Open-end wrench
It is used for removal and installation of air conditioning pipe joint in the evaporator
assembly
27# Open-end wrench
It is used for removal and installation of water hose joint of the evaporator
Cross screwdriver
It is used for removal and installation of evaporator mounting assembly
Ratchet wrench
It is used for removal and installation of captive bolts of evaporator
13# Socket
It is used for removal and installation of captive bolts of evaporator
Extended rod
It is used for removal and installation of captive bolts of evaporator
Plastic bag, tape
It is used for sealing up the pipe joints
Marking pen
It is used for marking the removed joints
Summary of Contents for CLG835H
Page 2: ......
Page 4: ...Contents January 24 2017 CLG835H...
Page 6: ...1 2 General Information January 24 2017 CLG835H...
Page 38: ...1 34 Machine Inspection Table January 24 2017 CLG835H...
Page 156: ...3 2 Power Train System January 24 2017 CLG835H...
Page 214: ...3 2 Power Train System January 24 2017 CLG835H...
Page 272: ...3 60 Testing and adjustment January 24 2017 Power Train Test CLG835H...
Page 276: ...4 4 Hydraulic System January 24 2017 CLG835H...
Page 552: ...6 2 Driver s Cab System January 24 2017 CLG835H...
Page 608: ...7 2 Structure January 24 2017 CLG835H...
Page 662: ...8 4 Electrical System January 24 2017 CLG835H...
Page 677: ...8 19 January 24 2017 Structure Function Principle CLG835H Power System P18E00014...