A/C system regular maintenance
CLG835H
The table below gives reference values about corresponding relation between pressure and tempera-
ture. Because the actual working pressure of air conditioning system is related to compressor speed,
sunlight intensity, evaporator air volume and other factors. Data in the table below are only for reference:
13. Open low pressure valve 3,
depress accelerator with the
aid of a companion, maintain
the accelerator to be 80% or
so, and observe high pres-
sure gauge and sight
glasses until the pressure
reaches an appropriate
value (refer to attached
table). And there are no bub-
bles in sight glass.
14. First turn off all the valves,
then remove the inflating
unit.
Ambient temperature
Indicating range of the high
pressure gauge
Indicating range of the low
pressure gauge
°C
Kg.f/cm
2
Kg.f/cm
2
15.5°C
8.4~10.5
1.57~1.9
21.1°C
10.5~12.6
1.57~1.9
26.6°C
12.6~14
1.67~2.1
32.2°C
14~15.4
1.67~2.1
35°C
15.4~16.4
1.77~2.1
37.7°C
16.1~17.5
1.77~2.1
40.5°C
17.5~19.3
1.9~2.4
43.3°C
18.2~21.8
1.9~2.6
Figures
Operation step
Tools
Summary of Contents for CLG835H
Page 2: ......
Page 4: ...Contents January 24 2017 CLG835H...
Page 6: ...1 2 General Information January 24 2017 CLG835H...
Page 38: ...1 34 Machine Inspection Table January 24 2017 CLG835H...
Page 156: ...3 2 Power Train System January 24 2017 CLG835H...
Page 214: ...3 2 Power Train System January 24 2017 CLG835H...
Page 272: ...3 60 Testing and adjustment January 24 2017 Power Train Test CLG835H...
Page 276: ...4 4 Hydraulic System January 24 2017 CLG835H...
Page 552: ...6 2 Driver s Cab System January 24 2017 CLG835H...
Page 608: ...7 2 Structure January 24 2017 CLG835H...
Page 662: ...8 4 Electrical System January 24 2017 CLG835H...
Page 677: ...8 19 January 24 2017 Structure Function Principle CLG835H Power System P18E00014...