Switch Management Commands
1992
User Guidelines
Auto enables the switch to deliver power to the powered device. The power
inline management parameter should be set to class-based mode to enable
power negotiation via LLDP-MED. Dell EMC Networking PoE-enabled ports
should not be connected to other Power Sourcing Equipment (PSE) with PoE
enabled. If the switch detects PSE equipment supplying power to a port, PoE
power is disabled on the port. If a port supplying power issues an input power
detected (0x24) status and no device is attached, the port should not be used
as a possible short may exist.
Default Value
The default value is auto, that is, device discovery is enabled and the port is
capable of delivering power.
Examples
console(config)#interface gigabitethernet 1/0/1
console(config-if-Gi1/0/1)# power inline auto
power inline detection
Use the
power inline detection
command to configure the detection type
that tells which types of PD’s will be detected and powered by the switch. Use
the
no
form of this command to set the detection type to the default.
Syntax
power inline detection
[unit unit-id]
{
dot3at|legacy
}
no power inline detection
• dot3at
—IEEE 802.3at 4-point detection only.
•
legacy
—IEEE 802.3at 4-point detection followed by legacy
capacitive detection.
•
unit unit-id
—The specific stack member to be configured.
Default Configuration
The default value is legacy.
Summary of Contents for N1100-ON
Page 2: ......
Page 4: ......
Page 258: ...Using the CLI 258 ...
Page 488: ...Layer 2 Switching Commands 488 Operational State Querier Operational version 1 ...
Page 656: ...Layer 2 Switching Commands 656 10 ...
Page 1128: ...Audio Visual Bridging Commands 1128 ...
Page 1186: ...Data Center Technology Commands 1186 ...
Page 1435: ...Layer 3 Routing Commands 1435 Number of Joins 7 Number of Groups 1 ...
Page 2330: ......
Page 2331: ...www dell com support dell com Printed in the U S A ...
Page 2332: ......