Tightening
9836 3521 01
335
Diagram 2:
Angle
Torque
Tstart
Torque Start
Astart
Angle Start
Dev
Deviation
Tstop
Torque Stop
Astop
Angel Stop
TRL
Torque Rate Low
TRH
Torque Rate High
T1
Torque at the end of Astart
A2
Angle at Tstop
Step
Tstart
T2 = Tstop
T1
Astart
Astop
A1
A2
Dev
TRH
TRL
Result var.:
"TR" (step torque rate) and "TR Dev" (step torque rate deviation).
Alarms:
Torque rate too low (TRL), Torque rate too high (TRH) and Too big deviation (DEV)
Trace
:
The calculated torque rate line and the Dev lines are shown as in the diagram above. The
lines are only shown when Torque vs. Angle is selected and Check limits are enabled in the
trace form (see View of trace curves).