Peripheral Devices
9836 3521 01
445
8.11.1.2 Supported message types
MID
Name
Implementation description
0001
Communication start
Enables communication
0002
Communication start acknowledge
0003
Communication stop
Disables communication
0004
Command error
0005
Command accepted
0010
Parameter set numbers upload request
Modes are used for parameter sets in PowerMACS.
0011
Parameter set numbers upload reply
0014
Parameter set “selected” subscribe
0015
Parameter set “selected”
Creation/download time for program run by first bolt in
selected mode. Mode number not 0 in start signal gives that
mode no according to start signal is used. Mode number 0
in start signal makes the station use the mode number it has
stored. When testbolt is run mode number is reset to the
mode number used before testbolt, when the testbolt cycle
is ready.
0016
Parameter set “selected” acknowledge
0017
Parameter set “selected” unsubscribe
0018
Select Parameter set
Selection of Mode. Mode number is sent to station. ModeNo
NOT_DEFINED (-32768) (test bolt not mode view) is not
reported as parameter set change and mode is reset to
original mode in station when the test bolt cycle has run.
0040
Tool data upload request
0041
Tool data upload reply
Tool serial number (Id 01) is reported as spaces ' '.
As Tool number of tightening (Id 02) is reported the number
of cycles run on the spindle controller of the TC holding the
epHan device (max value is 2147483647).
As Last calibration date (Id 03) is reported the time for when
the service flag was last reset (cycle count changes).
Controller serial number (Id 04) is reported as spaces ' '.
0042
Disable tool
Disables START signal in PLC. When the station controller
receives a START signal (from PLC or testbolt) a info event
is issued to report that the station is disabled if a Disable
tool signal has been received from the epHan device. When
a Disable tool signal is received during a cycle an
emergency stop is issued and the cycle stops. Emergency
stop event is reported.
0043
Enable tool
Enables START signal in PLC. Station controller is enabled
at startup. To enable the station controller when disabled an
Enable tool signal must be sent.
Summary of Contents for PowerMACS 4000
Page 2: ......
Page 46: ...System Architecture 46 9836 3521 01...
Page 267: ...Tightening 9836 3521 01 267...
Page 400: ...Tightening 400 9836 3521 01...
Page 486: ...Peripheral Devices 486 9836 3521 01...
Page 622: ...Peripheral Devices 622 9836 3521 01...
Page 664: ...References 664 9836 3521 01...
Page 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...