Tightening
9836 3521 01
343
Result var:
Delta T
Alarms:
Delta torque high (DTH) and Delta torque low (DTL).
Trace
:
No limits are shown in trace.
6.5.4.16 Low Spot Torque (only available for Gauging)
Parameters:
TH
(Maximum low spot torque),
TL
(Minimum low spot torque),
Start condition
,
Astart
(for Start condition Angle)
Set null position
(Store low position to Null position register)
Set low position
(Store low position to Low position register)
Function:
The lowest torque during the check is measured and compared to the limits (TH, TL). The
measurement starts when the angle
Astart
(measured from check start) has been passed.
If
Start condition
is
Step start
or
Zone start
the measurement starts directly when the
check starts.
The measurement ends then the step or zone ends. If it is running on step level the last
sample is taken at the shut off point of the step.
If
Set null position
or
Set low position
is set the low position, that is the angle where the
low spot torque was found, is stored in the corresponding position register. It is possible to
return to this position later with the step
Run to Position
.
Result var:
Low Spot T
Alarms:
Low spot torque high (LTH) and Low spot torque low (LTL).
Trace:
Torque vs. Angle
6.5.4.17 Check Position (only available for Gauging)
Parameters: PH
(Maximum distance to selected position),
PL
(Minimum distance to selected position),
Reference position
(Null, Half, Peak or Low position),
Function:
The distance to the selected position at the shut off point of the step is compared to the
limits
PH
and
PL
. Both limits are optional.
The distance is calculated as Distance = Reference Position
– Current Position, the result
can be both negative and positive.
Result var:
Position A
Alarms:
Position high (PH) and Position low (PL).
Trace
:
No limits are shown in trace.
Summary of Contents for PowerMACS 4000
Page 2: ......
Page 46: ...System Architecture 46 9836 3521 01...
Page 267: ...Tightening 9836 3521 01 267...
Page 400: ...Tightening 400 9836 3521 01...
Page 486: ...Peripheral Devices 486 9836 3521 01...
Page 622: ...Peripheral Devices 622 9836 3521 01...
Page 664: ...References 664 9836 3521 01...
Page 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...