Tightening
348
9836 3521 01
The
Failure during repair
alternatives are used when the station is in its Running Repair state,
that is when an error occurs during the repair.
Please note that the Retry alternative is
not
available for the steps located in the repair part of the
program. The steps in the repair part of the program are only intended for preparation of a repair.
CE steps do not have
Failure during repair
since all CE steps finishes the cycle (and thereby
ends any on-going repair).
The Failure during repair action only affects bolts that are active running repair. Bolts that are
waiting, or have finished their repair, are not affected. The following Failure during repair
alternatives are available in the main program:
Failing bolts
Failing group
Other bolts
Terminate
Terminate
Terminate
Terminate
Terminate
Wait
Terminate
Wait
Wait
Continue
Continue
Continue
Retry
Retry
Retry
Note!
No Retry is allowed as
Failure during repair
action when steps in the repair part are run.
The
Fatal failure
alternatives are used when a fatal error occurs for the bolt. It offers the following
alternatives:
Failing bolts
Failing group
Other bolts
Terminate
Terminate
Terminate
Terminate
Terminate
Wait
Terminate
Wait
Wait
The Fatal failure action affects all bolts that are not already terminated. That is, also the bolts that are
waiting while other bolts are being repaired may be ordered to Terminate.
Summary of Contents for PowerMACS 4000
Page 2: ......
Page 46: ...System Architecture 46 9836 3521 01...
Page 267: ...Tightening 9836 3521 01 267...
Page 400: ...Tightening 400 9836 3521 01...
Page 486: ...Peripheral Devices 486 9836 3521 01...
Page 622: ...Peripheral Devices 622 9836 3521 01...
Page 664: ...References 664 9836 3521 01...
Page 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...