Tightening
312
9836 3521 01
Diagram 2:
Angle
Torque
Step
TStart
Threshold Torque
MinT
Min Torque Limit
TStart
MinT
Restriction active
Alarms
:
Min Torque Restriction (MTR) if the torque drops below MinT
Trace
:
MinT is showed in trace as a horizontal line from TStart to step stop when Torque vs. Angle
is selected. Restriction limits must be enabled in the trace form (see