PLC
9836 3521 01
231
5.3.2
Bolt variables
The following inputs can be used to monitor the status of each individual bolt:
Variable
Type
Use
COMPERRORS
ARRAY[1..50]
OF BYTE
Reports the most commonly reported bolt errors for each of the
bolts.
The respective bits have the following meaning (bit 0 is the least
significant):
0: (value 1)
THM (Torque High Monitoring)
1: (value 2)
TLM (Torque Low Monitoring)
2: (value 4)
AHM (Angle High Monitoring)
3: (value 8)
ALM (Angle Low Monitoring)
4: (value 16) OK (Bolt status OK).
This bit is set if the bolts final status is
OK.
5: (value 32) Reserved
6: (value 64) Reserved
7: (value 128) Reserved
Summary of Contents for PowerMACS 4000
Page 2: ......
Page 46: ...System Architecture 46 9836 3521 01...
Page 267: ...Tightening 9836 3521 01 267...
Page 400: ...Tightening 400 9836 3521 01...
Page 486: ...Peripheral Devices 486 9836 3521 01...
Page 622: ...Peripheral Devices 622 9836 3521 01...
Page 664: ...References 664 9836 3521 01...
Page 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...