PLC
228
9836 3521 01
Variable
Type
Use
STATIONSTATUS_EXT
STATION_STATUS_
EXT_TYPE
This variable indicates the station status of the last
tightening.
It is a structure containing the following BOOL flags:
OK
True if result is OK or OK after RM (OKR).
OKRM
True if result is OK after RM.
NOK
True if result is NOK or Stop and Terminate Not
OK (TERMNOK).
TERMNOK
True if result is Stop and Terminate Not
OK (TERMNOK).
The value of this variable is only changed as a result of
running a cycle. When the station is started all flags are
reset and when the cycle is ready the relevant flags are
set.
Use this variable together with STATIONSTATE as an
alternative to the STATIONSTATUS input.
STATIONSTATE
STATION_STATE_
TYPE
This variable indicates the current state of the station.
It is a structure containing the following BOOL flags:
IDLE
True if the station is idle, that is, it is not
executing a cycle.
RUNNING
True if the station is running a cycle, that
is, it is not idle. This includes evaluating and waiting for
PLC as well.
EVALUATING
True if the station is evaluating the
results from the bolts.
WAITING_FOR_PLC
True if the station is waiting for
a new START signal due to that some bolt is executing
a step that requires a this to continue.
Use this variable together with STATIONSTATUS_EXT as
an alternative to the earlier STATIONSTATUS input.
Summary of Contents for PowerMACS 4000
Page 2: ......
Page 46: ...System Architecture 46 9836 3521 01...
Page 267: ...Tightening 9836 3521 01 267...
Page 400: ...Tightening 400 9836 3521 01...
Page 486: ...Peripheral Devices 486 9836 3521 01...
Page 622: ...Peripheral Devices 622 9836 3521 01...
Page 664: ...References 664 9836 3521 01...
Page 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...