Peripheral Devices
528
9836 3521 01
byte
PowerMACS
Input area
CC-Link master
Output
0
PLC bool AT 3000.0
Y0 (bit 0)
:
PLC bool AT 3000.1
Y1 (bit 1)
:
:
:
0
PLC bool AT 3000.7
Y7 (bit 7)
1
PLC bool AT 3001.0
Y8 (bit 8)
:
:
:
7
PLC bool AT 3007.7
Y
Data
bits
Y63 (bit 63)
8+9
PLC word AT 3008
Word 1
10+11
PLC word AT 3010
Word 2
:
:
:
22+23
PLC word AT 3022
RWw
Data
word
registers Word 8
byte
PowerMACS
Output area
CC-Link master
Input
0
PLC bool AT 3300.0
X0 (bit 0)
:
PLC bool AT 3300.1
X1 (bit 1)
:
:
:
0
PLC bool AT 3300.7
X7 (bit 7)
1
PLC bool AT 3301.0
X8 (bit 8)
:
:
:
7
PLC bool AT 3307.7
X
Data
bits
X63 (bit 63)
8+9
PLC word AT 3308
Word 1
10+11
PLC word AT 3310
Word 2
:
:
:
22+23
PLC word AT 3322
RWr
Data
word
registers Word 8
Two LED‟s on the AnyBus module indicate the status of the CC-Link. These LED:s can also be displayed
from the
System Map
form, see
Indication of the fieldbus node’s
for how to do this.
The function of the respective LED is as follows:
LED
Function
Indicates
1
Run
Steady off
– No network participation, timeout status (no power).
Steady Green
– Participating, normal operation.
Steady Red
–
Major fault (FATAL error).
2
Error
Steady off
– No error detected (no power).
Steady Red
– Major fault (Exception or FATAL event).
Red, flickering
– CRC error (temporary flickering).
Red, flashing
– Station Number or Baud rate has changed since startup
(flashing)
Summary of Contents for PowerMACS 4000
Page 2: ......
Page 46: ...System Architecture 46 9836 3521 01...
Page 267: ...Tightening 9836 3521 01 267...
Page 400: ...Tightening 400 9836 3521 01...
Page 486: ...Peripheral Devices 486 9836 3521 01...
Page 622: ...Peripheral Devices 622 9836 3521 01...
Page 664: ...References 664 9836 3521 01...
Page 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...