Peripheral Devices
9836 3521 01
469
Result data:
Bolt level data
This table describes the data sent to PLUS if Bolt level data is reported
PI
Description
Value sent, PW
Comment
001
Torque
Bolt T
The value reported from “Final Torque at cycle end”
monitoring.
The torque is multiplied by 100 and is sent as an integer (2
decimals rounded).
002
Angle of rotation
Bolt A
The value reported from
“Angle from threshold to Cycle
End
” monitoring.
Are always sent as an integer with unit degrees. The value
is rounded to nearest integer.
003
Step number
0
The step number will always be 0 to indicate that it is bolt
data
Step level data
This table describes the data sent to PLUS if step level data is reported. All the step data will come from
the same step.
PI
Description
Value sent, PW
Comment
001
Torque
SO T,
“Shut off torque”
The value reported from a “Check shut off torque” check.
The torque is multiplied by 100 and is sent as an integer (2
decimals rounded).
002
Angle of rotation
A
The value reported by a “Check angle” check.
Are always sent as an integer with unit degrees. The value
is rounded to nearest integer.
003
Step number
Step No
The number of the step that produced the other data.
004
Current
Peak C
The highest current reached during the step. Reported by a
“Check peak torque” check running on channel T3.
The current is converted to torque, which is then multiplied
by 100 and sent as an integer (2 decimals rounded).
Summary of Contents for PowerMACS 4000
Page 2: ......
Page 46: ...System Architecture 46 9836 3521 01...
Page 267: ...Tightening 9836 3521 01 267...
Page 400: ...Tightening 400 9836 3521 01...
Page 486: ...Peripheral Devices 486 9836 3521 01...
Page 622: ...Peripheral Devices 622 9836 3521 01...
Page 664: ...References 664 9836 3521 01...
Page 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...