Peripheral Devices
474
9836 3521 01
Field
Bytes
Value sent
Version
2
“
3
“
Character Code
20
“
ISO-8859-1
“
Sequence Number
4
Length of User Data
6
Byte Order
1
Always 0 = Intel byte order
Maintenance Sequence User Data
Field
Bytes
Value sent
Manufacturer
Identification
5
“
AC
“
Facility Type
2
1 if Facility type = “Fastening” and 4 if = “Adjustment,
for the moment always 1
Date
10
Cycle start time
Time
8
Cycle start time
Maintenance Sequence,
AFU-number
30
See description below.
Event Number
15
Empty
Maintenance Sequence
Text
50
“Bolt name” + “-“ + “Program name”
e.g. “
Bolt 01-Test run
”, “
Left bolt-Tighten left bolt
”
Tool-ID
10
Spindle serial number from the spindle setup, if it is specified.
Unit Carrier ID
10
Result variable Id res 2, only the 10 first characters are used.
Type
10
Result variable Id res 3, only the 10 first characters are used.
Identification
30
Result variable Id res 1 or Wp ID, depending on the selection in the
I-P.M. reporter, only the 30 first characters are used.
Additional ID
10
Result variable Id res 4, only the 10 first characters are used.
Curve
1
0 = without trace
1 = with trace
Status
2
0 = OK or OKR
1 = NOK, TERMNOK or NOKRM
This is always the bolt status; a bolt can be OK even if the station is
NOK.
Mode
1
Always 0 = automatic mode
Loosen
1
“
“ = not available.
Number of additional
information
2
Always “
0
“, no additional information is available
Number of Error Codes
2
Error Code (for every
error)
5
See table below for possible error codes
Summary of Contents for PowerMACS 4000
Page 2: ......
Page 46: ...System Architecture 46 9836 3521 01...
Page 267: ...Tightening 9836 3521 01 267...
Page 400: ...Tightening 400 9836 3521 01...
Page 486: ...Peripheral Devices 486 9836 3521 01...
Page 622: ...Peripheral Devices 622 9836 3521 01...
Page 664: ...References 664 9836 3521 01...
Page 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...