6.5.5.1 Checking the bolt status
The first thing that the Reject Management function does when a step fails is to figure out whether or not
the step can be repaired. This is decided by the bolts current statuses.
At each synchronized step all bolts will be assigned a status. This status is the result of all checks made in
the step, comprising the restriction tests, the step checks, hardware checks, etc. The resulting overall
status for a bolt will be one of the following:
Status of all restrictions, checks, etc. of the step
Bolt status
All checks are Acceptable
Acceptable
At least one check is Repairable and none is Fatal
Repairable
At least one check is Fatal
Fatal