6.5.2.5 TC - Run until Torque with Current Control
Step type Id:
3
Parameters
: T (Torque), DIR (Direction).
Function
:
Run spindle, in DIR direction, until torque is T using current control.
The target torque T is converted to a corresponding motor current using the spindle
parameters
T/C Factor, T/C Correction Factor
and
Gear ratio
. This current is then set as
reference to the motor servo. The step is stopped when the servo reaches its set point.
Diagram
:
Angle
Torque
T
Target Torque
T
Step
Trace
:
Torque T is shown as a horizontal line from step start to step stop in trace when Torque vs.
Time is selected. Control parameters must be enabled in the trace form (see