Appendix
9836 3521 01
633
Code
Comp
Code
Type
Severity Event string
1102
205
Hardware
Error
Low battery voltage on TC %d
1106
209
System
Error
System TC on addr 0x%x received setup from other system TC
with addr 0x%x
1107
210
System
Error
TC %d received setup from 2 system TCs: 0x%x and 0x%x
1108
890
System
Error
TC %d Device type %d uses a serial channel, this is only
allowed on PTC
1150
441
System
Error
TC %d restarted due to fatal SW error (code: %s, sub code:
0x%x)
1401
211
General
Warning
Printer on TC %d (port %d) does not support Device Command
= %d
1500
212
Ext. com
Error
ID write error %d on TC %d, port %d
1501
213
Ext. com
Error
ID read error %d on TC %d, port %d
1502
214
Ext. com
Error
ID read error on TC %d, port %d. Invalid start char. ASCII =
0x%x
1503
215
Ext. com
Error
ID read error on TC %d, port %d. Unable to read tag, Data = %d
1504
216
Ext. com
Error
ID write error on TC %d, port %d. Unable to write tag, Data = %d
1506
530
Ext. com
Error
ID device on TC %d, failed to write process data
1507
886
Ext. com
Error
ID read error on TC %d, port %d. Tot. length of string was more
than %d chars
1508
887
Ext. com
Error
ID read error TC %d, port %d. Start char was never received,
must be ASCII=0x%x
1601
218
System
Error
Device init. error (TC %d, device %d, info %d)
1602
219
Ext. com
Error
Illegal link message received (TC %d, device %d, info %d)
1603
220
Ext. com
Error
Device is not on a PLC TC (TC %d, device %d)
1604
221
Ext. com
Error
Missing sequence number (TC %d, device %d, expected seq.
no %d)
1605
222
Ext. com
Error
Received setup is too big (TC %d, device %d)
1606
891
Ext. com
Error
Device is not on the System TC (TC %d, device %d)
1701
223
System
Error
Fieldbus on TC %d has no contact with PLC
1702
224
System
Error
Fieldbus on TC %d can not read process data (err %d)
1703
225
System
Error
Fieldbus on TC %d can not write process data (err %d)
1704
226
Ext. com
Error
Fieldbus on TC %d can not read from board (err %d)
1705
227
Ext. com
Error
Fieldbus on TC %d can not write to board (err %d)
1706
228
Ext. com
Error
Fieldbus on TC %d rec. a req. (0x%x) that requires Data bytes
In >= %d
1707
229
Ext. com
Error
Fieldbus on TC %d rec. a req. (0x%x) that requires Data bytes
Out >= %d
Summary of Contents for PowerMACS 4000
Page 2: ......
Page 46: ...System Architecture 46 9836 3521 01...
Page 267: ...Tightening 9836 3521 01 267...
Page 400: ...Tightening 400 9836 3521 01...
Page 486: ...Peripheral Devices 486 9836 3521 01...
Page 622: ...Peripheral Devices 622 9836 3521 01...
Page 664: ...References 664 9836 3521 01...
Page 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...