Set Up and Maintenance
9836 3521 01
155
4.6.6.4 Order of execution
The below text describes the sequence of actions that can occur:
IF (Static Zero Offset test) THEN
Measure the Static Zero Offset;
Save as Zero Offset compensation value if within limits;
ENDIF
IF (Dynamic Zero Offset test OR Angle test) THEN
First run in the forward direction and then in the backward direction;
Measure average torque and angle pulses in both directions;
IF (Dynamic Zero Offset test) THEN
Check the measured Dynamic Zero Offset;
Save as Zero Offset compensation value if within limits;
ENDIF
IF (Angle test) THEN
Check that both the measured angles are within specified limits;
ENDIF
ENDIF
IF (Flying Zero Offset test) THEN
Run forward a programmable time from the start of the diagnostic step (do not measure);
Start measuring the torque and run another programmable time;
Save as Zero Offset compensation value if within limits;
ENDIF
Summary of Contents for PowerMACS 4000
Page 2: ......
Page 46: ...System Architecture 46 9836 3521 01...
Page 267: ...Tightening 9836 3521 01 267...
Page 400: ...Tightening 400 9836 3521 01...
Page 486: ...Peripheral Devices 486 9836 3521 01...
Page 622: ...Peripheral Devices 622 9836 3521 01...
Page 664: ...References 664 9836 3521 01...
Page 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...