PLC
224
9836 3521 01
Variable
Type
Use
GENOUT_1 ...
GENOUT_5
INT
General output. Can be used for selection of double encoders or
change of spindle direction. See chapter: Spindle Set Up.
FREESTRING
STRING(40)
The value of this output can be included in the cycle data result as
the station level result variable "Free Str". Sampled on the positive
edge of START.
FREESTRING2
STRING(40)
The value of this output can be included in the cycle data result as
the station level result variable "Free Str 2". Sampled on the positive
edge of START.
FREESTRING3
STRING(40)
The value of this output can be included in the cycle data result as
the station level result variable "Free Str 3". Sampled on the positive
edge of START.
FREENUM1
DINT
The value of this output can be included in the cycle data result as
the station level result variable "Free No 1". Sampled on the positive
edge of START.
FREENUM2
DINT
The value of this output can be included in the cycle data result as
the station level result variable "Free No 2". Sampled on the positive
edge of START.
DISABLE_TESTBOLT
BOOL
Set this output TRUE to disable the usage of the ToolsTalk
PowerMACS Test Bolt form for this station. See also chapter: Test
Bolts.
ACKACCESSEVENT
BOOL
Set this output True to mark all events of type "Access" as observed
(see View Event Log and PLC Event handling).
ACKPOWERUPEVENT
BOOL
Set this output True to mark all events of type "Power up" as
observed (see View Event Log and PLC Event handling).
ACKCHKEVENT
BOOL
Set this output True to mark all events of type "Check" as observed
ACKSWEVENT
BOOL
Set this output True to mark all events of type "Software" as
observed (see View Event Log).
ACKSYSERREVENT
BOOL
Set this output True to mark all events of type "System error" as
observed (see View Event Log).
ACKMODEVENT
BOOL
Set this output True to mark all events of type "Modification" as
observed (see View Event Log).
ACKHWEVENT
BOOL
Set this output True to mark all events of type "Hardware" as
observed (see View Event Log).
ACKEMERGEVENT
BOOL
Set this output True to mark all events of type "Emergency stop" as
observed (see View Event Log).
ACKGENERALEVENT
BOOL
Set this output True to mark all events of type "General" as
observed (see View Event Log).
ACKXCOMEVENT
BOOL
Set this output True to mark all events of type "External
communication" as observed (see View Event Log).
ACKSETUPEVENT
BOOL
Set this output True to mark all events of type "Set up" as observed
(see View Event Log).
Summary of Contents for PowerMACS 4000
Page 2: ......
Page 46: ...System Architecture 46 9836 3521 01...
Page 267: ...Tightening 9836 3521 01 267...
Page 400: ...Tightening 400 9836 3521 01...
Page 486: ...Peripheral Devices 486 9836 3521 01...
Page 622: ...Peripheral Devices 622 9836 3521 01...
Page 664: ...References 664 9836 3521 01...
Page 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...