6.5.4.12 Check time
Parameters:
TIH
(Time high),
TIL
(Time low)
Function:
The time from when the step starts until it ends is measured and checked to be between the
high limit TIH and the low limit TIL.
Both limits are optional. Leaving them blank disables the check but the result value is still
calculated and reported.
Diagram:
Time
Torque
TIH
TIL
TIL
Time Low
OSHT
Overshoot time
TIH
Time High
Step
Shut-off point
OSHT
Step time
Result var.:
"Time" (step time).
Alarms:
Step time high (TIH) and Step time low (TIL).
Trace
:
There are no limits in trace for this check.
6.5.4.13 Check Yield Point Angle
Parameters:
Yield Angle high, Yield Angle low, Torque start, No degrees, Angle distance, DIFF, Stop
condition