background image

All units have an internal circuit breaker protecting the DC output. If the breaker opens, turn 

the  power  off  and  wait  a  few  minutes  to  allow  the  circuit  breaker  to  reset.  If  the  breaker  is 

continually opening it could mean you have a problem with the tool or the tool power cord, 

the power supply or have selected the wrong screwdriver or power supply for the application. 

Contact HIMAX for help to resolve the problem.     

  

The AC FUSE on the CLT-50 power supply is located in   

the IEC connector on the back of the units along with a spare   

fuse. The spare fuse is located in the rear “pocket” of the fuse   

holder.   

  

NOTE 

The CLT-50 has a hard wired cord and can be operated   

on 110-115 VAC ONLY. The CLT-50S AC FUSE is inside the   

case and is not recommended to be replaced by the user. 

 

SPECIFICATIONS 

Features 

CLT-50 

CLT-50S 

Input voltage 

AC 115/ 230V~ 50/60Hz 

Output voltage 

DC    20V/30V 

    LOW/HI    2 Class converter   

Output current 

DC 2.5A

MAX

 

DC 1.5A 

—(

MAX

 

Figure dimension 

100(W)×190(D)×95(H) 

70(W)×125(D)×60(H) 

Weight 

2.8Kg 

1Kg 

AC power cord length 

1.8m   

1.5m 

Application area 

TL2000(T2)/3000(T3) 

TL4000(T4)/5000(T5) 

TL6000(T6)/6500(T65) 

TL2000(T2)/ 

TL3000(T3)/ 

TL4000(T4) 

 

NINBO TAI-LI A.E.T. CO., LTD 

No.168, Yingchun Road, Wangchun Industry Development Area,   

Gaoqiao, Yinzhou District, Ningbo, China 

Tel

0574-87368178    Fax

0574-87368078 

www.ehimax.com 

 

 

 

HIMAX 

ELECTRIC SCREWDRIVER POWER SUPPLY 

CLT-50 / CLT-50S 

INSTRUCTION MANUAL

 

 

 

 
 
 
 
 

Instruction

 

 

CLT-50/CLT-50S power supply is applied to TL/T series electric screwdrivers. 

 

Please notice whether the electric screwdriver connects to the power supply with 5P     

connecting wire in correct direction. 

 

Ascertain that the power supply is connected at 110~230V 50/60Hz, and turn on the power. 

When the LED red light illuminates, the machine is ready to work. 

 

User can change the output voltage to LOW: 25V or HI: 30V by turning the HI/LOW switch, 

to convert the speed of the electric screwdriver. 

Electric Figure: 

 

Remarks

 

F1/Fuse 

C1/Capacitor 

T1/Transformer 

K2/Speed switch 

RD/Indicator lamp 

K1/Power switch 

PCB/control plate 

OUT/socket 

CLT-50/CLT-50S power supply can be applied to HIMAX TL/T series or other compatible 
electric screwdriver brands, which adopts the advanced electronic circuit, the SMT surface 
technology  of welding and the branded  imported component  for control circuit to realize 
the  supplying  of  high-quality  direct  current;  The  product  is  characterized  by  stable 
performance, strong power, extreme safety and easy maintenance. 

Reviews: