background image

 

INTEGRATED 

POWER DESIGNS

 

 

300 Stewart Road 

Wilkes-Barre, PA 18706 USA 

Phone: (570) 824-4666

 

Web: www.ipdpower.com 

Email: [email protected] 

Fax: (570) 824-4843 

 

DRAWING NO:     1080023 
REVISION:            34 

REL-185 SERIES OPERATING INSTRUCTIONS 

 

INPUT RATING:  

100-240VAC, 4 A, 50-60 Hz. 

 

OUTPUT RATING:  

185 Watts Maximum Total Continuous Output Power with 300 LFM Forced Air. 

 

135 Watts Maximum Total Continuous Output Power Convection Cooled. 

 

110 Watts Maximum Total Continuous Output Power Convection Cooled with Chassis and Cover. 

 

MODEL LISTING: 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

                    

 

 
 

 

NOTES: 

1. Total current from Outputs 1 and 2 must not exceed 20 Amps with convection cooling. 

 

2. Total current from Outputs 3 and 4 must not exceed 3 Amps with convection cooling. 

 

3. Rated 15 Amps maximum with convection cooling. 

 

4. Rated 27 Amps maximum with convection cooling. 

 

5. A suffix may be added to the model number to indicate the following optional configurations: 

 

    (CH-chassis, CO-cover, IO-isolated outputs, RE-remote inhibit, TS-terminal strip) 

 

6. Output is ES3 type.

 

 

Model 

Output 1

(1)

 

Output 2

(1) 

Output 3

(2) 

Output 4

(2)

 

REL-185-4001 

+3.3VDC/20A

(3)

 

+5VDC/10A

 

+12VDC/2A

 

 

 

-12VDC/2A

 

 

REL-185-4002 

+5VDC/20A

(3)

 

+3.3VDC/10A                  

+12VDC/2A

 

 

 

-12VDC/2A

 

 

REL-185-4003 

+5VDC/20A

(3)

 

+3.3VDC/10A                  

+15VDC/2A

 

 

 

-15VDC/2A

 

REL-185-4004 

+5VDC/20A

(3)

 

-5VDC/10A 

 

+12VDC/2A

 

 

 

-12VDC/2A

 

 

REL-185-4005 

+5VDC/20A

(3)

 

-5VDC/10A 

 

+15VDC/2A

 

 

 

-15VDC/2A

 

REL-185-4006 

+5VDC/20A

(3)

 

+24VDC/3A

  

+12VDC/2A

 

 

 

-12VDC/2A

 

 

REL-185-4007 

+5VDC/20A

(3)

 

+24VDC/3A

  

+15VDC/2A

 

 

 

-15VDC/2A

 

REL-185-4008 

+3.3VDC/20A

(3)

 

+6.7VDC/5A

  

+12VDC/2A

 

 

 

-6.7VDC/2A 

 

 

REL-185-4009 

5VDC/15A 

12VDC/4A 

28VDC/0.8A

(6) 

12VDC/2A 

REL-185-4010 

5VDC/20A 

5VDC/10A 

24VDC/1A

(6)

 

24VDC/1A

(6)

 

REL-185-3001 

+5VDC/20A

(3)

 

+12VDC/5A

  

----- 

-12VDC/3A

 

 

REL-185-3002 

+5VDC/20A

(3)

 

+15VDC/4A 

----- 

-15VDC/3A

 

 

REL-185-2001 

+3.3VDC/20A

(3)

 

+5VDC/10A

 

----- 

----- 

REL-185-2002 

+5VDC/20A

(3)

 

+12VDC/8A

  

----- 

----- 

REL-185-2003 

+5VDC/20A

(3)

 

+24VDC/4A

  

----- 

----- 

REL-185-2004 

+12VDC/10A

 

 

-12VDC/4A 

----- 

----- 

REL-185-2005 

+15VDC/8A 

 

-15VDC/5A

 

----- 

----- 

REL-185-2006 

+15VDC/6A 

+24VDC/4A 

 

----- 

----- 

REL-185-2007 

+35VDC/3.5A

 

+12VDC/5.2A

  

----- 

----- 

REL-185-1001 

2.5VDC/37A

(4)

 

----- 

----- 

----- 

REL-185-1002 

3.3VDC/37A

(4)

 

----- 

----- 

----- 

REL-185-1003 

5VDC/37A

(4)

 

----- 

----- 

----- 

REL-185-1004 

12VDC/15.4A

 

----- 

----- 

----- 

REL-185-1005 

15VDC/12.3A 

----- 

----- 

----- 

REL-185-1006 

24VDC/7.7A

  

 

----- 

----- 

----- 

REL-185-1007 

28VDC/6.6A 

----- 

----- 

----- 

REL-185-1008 

48VDC/3.8A 

----- 

----- 

----- 

REL-185-1009 

6.3VDC/29A

 

 

 

----- 

----- 

----- 

REL-185-1010 

31VDC/6A 

----- 

----- 

----- 

 

 

 

 

 

 

 

 

 

 

 

                           DECLARATION OF CONFORMITY

 

 

Manufacturer:                            Integrated Power Designs, Inc. 
Manufacturer’s Address:           300 Stewart Road, Wilkes-Barre,  PA 18706 USA 
Product Type:                            Switchmode AC-DC Power Supply 

 

Declares all models listed above including all options are in compliance with the following European Community Directives: 

 

Low Voltage Directive 2014/35/EU of 26 February 2014 
RoHS Directive 2015/863/EU of 31 March 2015 

 

As well as with the requirements set out in the Laws of the United Kingdom relating to and applying the following standards: 

 

Electrical Equipment (Safety) Regulations 2016 SI No. 1101  

BS EN 62368-1:2014  

Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012 SI No. 3032 + 2019 SI No.492 

 

In addition, all models are Certified to be in compliance with applicable requirements of UL 62368-1:2014, ANSI/AAMI ES60601:2005/(R) 2012, IEC 62368-
1:2014 and IEC 60601-1:2005/A1:2012 including all EU national deviations, CAN/CSA-C22.2 No. 62368-1-14, CAN/CSA- C22.2 No. 60601-1:2014, EN 
62368-1:2014 and EN 60601-1:2006/A1:2013. 

 

BY: 

Steven Thompson- President 

EUROPEAN CONTACT:

 

UK CONTACT: 

 

 

 

Compumess Elektronik GmbH 

Lise-Meitner-Strasse 1 

85716 Unterschleiβheim 

Telephone (089) 32 15 01-0 

ALL PSU LTD 

Laser Quay, Culpeper Close 

Rochester Kent ME2 4HU 

Tel : 01634 725527 

 

PLACE: 

Integrated Power Designs 

 

300 Stewart Road, Wilkes-Barre, PA 18706 USA 

DATE: 

February 16, 2021 

 

 

 

 

Reviews: